Features of the IS76 Beacon System
Ferrite antenna offers a better defined capture range that is less dependent on the
surrounding building material
The antenna may be installed in or outdoors
Up to 230 user selectable position (location) codes (001 to 230)
Up to 24 user selectable "Wandering" codes (231 to 254)
Supervision of the beacon functionality
IS76 Ferrite Antenna
The antenna is best fitted to be mounted vertically on a door's frame. In any case, the middle
of the antenna should be at a height of 40 inches (1 meter) from the floor. The antenna has
to be fixed by two screws, according to the figure below.
Figure 2
Remove the cover caps at both ends of the antenna by sliding them against the outside
Secure the antenna against the wall with both screws
Replace the cover caps by sliding them over the housing
Note:
Even if the functionality of the Ferrite Beacon System is not affected by the presence
of metallic items, it is not recommended to fix the antenna directly against such items.
In order to avoid overheating of the IS76 Beacon Controller, install the antenna at least
0.6 in (1.5 cm) away from metallic frames or surfaces.
1.2 in +
/
- 0.04 in
(
30mm +
/
- 1mm
)
21.3 in +
/
- 0.04 in
(
540mm +
/
-1mm
)
2 X
Ø 0.21 in (5.5mm)
23.6 in +
/
-0.4 in
(
600mm +
/
-10mm