Install Instructions
Table Of Contents
- Table of Contents
- 1 Key to symbols and safety instructions
- 1.1 Key to symbols
- 1.2 General safety instructions
- 2 Scope of delivery
- 3 Information about the appliance
- 3.1 Proper use
- 3.2 Overview of boiler types
- 3.3 Rating plate
- 3.4 Appliance description
- 3.5 Accessories
- 3.6 Product dimensions and minimum clearances
- 3.7 Appliance layout heating boiler KBR..-3A
- 3.8 Appliance layout combi boiler KWB..-3A
- 3.9 Electrical wiring heating boiler KBR..-3A
- 3.10 Electrical wiring combi boiler KWB..-3A
- 3.11 Technical data heating boiler KBR 16-3
- 3.12 Technical data heating boiler KBR 21 -3
- 3.13 Technical data heating boiler KBR 28-3
- 3.14 Technical data heating boiler KBR 35-3
- 3.15 Technical data heating boiler KBR 42-3
- 3.16 Technical data combi boiler KWB 28-3
- 3.17 Technical data combi boiler KWB 35 - 3
- 3.18 Technical data combi boiler KWB 42 - 3
- 3.19 Condensate composition
- 4 Regulations
- 5 Common Applications of KBR boilers
- 6 Installation
- 6.1 Installation and operation
- 6.1.1 Notes on installation and operation
- Fill and make-up water for the heating system
- Recommended steps for commissioning a new or retrofit boiler installation
- Recirculation pump/DHW recirculation lines
- Open vented heating systems
- Gravity heating systems
- Galvanized radiators or pipes.
- Plastic pipe work
- Use of a room temperature control
- Primary-secondary piping or a Low Loss Header (LLH)
- Water Chemistry Guidelines
- Corrosion inhibitors
- Boiler sealer
- LPG
- 6.1.2 Other important information
- 6.1.1 Notes on installation and operation
- 6.2 Comparing the size of the integrated expansion vessel (KWB-3A boiler only)
- 6.3 KBR..-3A appliances (heating boilers): Selecting an expansion vessel
- 6.4 Selecting the installation location
- 6.5 Low Loss Header (LLH) utilization
- 6.6 Locating the appliance
- 6.7 Installing a low water cut off (LWCO)
- 6.8 Connecting flue gas accessories
- 6.9 Testing gas and water connections for leaks
- 6.1 Installation and operation
- 7 Making the electrical connections
- 8 Commissioning
- 8.1 Before operating the appliance
- 8.2 Switching the appliance ON/OFF
- 8.3 Setting up space heating
- 8.4 Programming the FW 200 heating control unit (optional accessory)
- 8.5 FW 200 outdoor reset heating control quick start (optional accessory)
- 8.6 After commissioning
- 8.7 KBR..-3A appliances (heating boilers) with DHW tank: Setting the DHW temperature
- 8.8 KWB..-3A appliances (combi boilers): Setting the DHW temperature
- 8.9 Setting manual summer mode
- 8.10 Setting frost protection
- 8.11 Activating the key pad lock
- 9 KBR..-3A appliances (heating boiler) with DHW tank: Thermal disinfection
- 10 Boiler circulator
- 11 Heatronic boiler control settings
- 11.1 Guideline to service functions
- 11.2 Overview of the service functions
- 11.3 Description of the service functions
- 11.3.1 First service level
- Service function 1.A: Maximum space heating output
- Service function 1.b: Maximum DHW output
- Service function 1.E: Pump mode for space heating operation
- Service function 1. F: Pump mode (only heating boiler KBR..-3A)
- Service function 2.A: Heating circuit pump lockout time (only heating boiler KBR..-3A)
- Service function 2.b: Maximum supply temperature
- Service function 2.C: Purging function
- Service function 2.d: Thermal disinfection (legionella protection)
- Service function 2.F: Operating mode
- Service function 3.A: Automatic anti-cycle function
- Service function 3.b: Set anti-cycle time
- Service function 3.C: Switching differential
- Service function 3.d: Minimum output (heating and DHW)
- Service function 3.E: Cycle time, keeping DHW hot (only combi boiler KWB..-3A)
- Service function 3.F: Constant DHW period (only combi boiler KWB..-3A)
- Service function 4.b: Maximum heat exchanger temperature (only combi boiler KWB..-3A)
- Service function 4.d: Audible fault warning tone
- Service function 4.E: Appliance type
- Service function 4.F: Condensate trap filling sequence
- Service function 5.A: Reset inspection interval
- Service function 5.b: Fan post purge time
- Service function 5.E: Functionality of black plug in boiler junction box
- Service function 5.F: Set inspection interval
- Service function 6.A: Display the latest fault code
- Service function 6.b: Room temperature control, current voltage, terminal 2
- Service function 6.C: Supply temperature required by weather compensation control
- Service function 6.d: Current DHW turbine flow rate (only combi boiler KWB..-3A)
- Service function 7.A: Indicator lamp for burner operation / faults
- Service function 7.b: 3-way valve in center position
- Service function 7.d: Connecting an external supply or low-loss header temperature sensor
- Service function 7.E: Building drying function
- Service function 0.A: Do not use this setting!
- Service function 0.d: Altitude adjustment
- Service function 0.E: Metric or US customary units
- 11.3.2 Second service level
- Service function 8.A: Software version
- Service function 8.b: Code plug number
- Service function 8.C: GFA Gas burner control unit status
- Service function 8.d: GFA Gas burner control unit fault
- Service function 8.E: Restore boiler to factory settings
- Service function 8.F: Permanent ignition
- Service function 9.A: Constant mode
- Service function 9.b: Current fan speed
- Service function 9.C: Current boiler output
- Service function 9.d: Set fan start speed
- Service function 9.E: Turbine signal delay (only combi boiler KWB..-3A)
- Service function 9.F: Heating zone pump post purge
- Service function A.b: Display DHW temperature
- Service function A.C: Display DHW tank temperature
- Service function b.F: Solar DHW backup heating delay (only combi boiler KWB..-3A)
- Service function C.d: Display current heat demand
- 11.3.1 First service level
- 12 Gas type conversion
- 13 Flue gas test
- 14 Environmental responsibility/disposal
- 15 Inspection and maintenance
- Heat exchanger
- Heatronic boiler control
- Notes on installation and operation
- After the inspection/maintenance
- 15.1 Description of various steps
- 15.1.1 Calling up the latest fault (service function 6.A)
- 15.1.2 Fresh water filter (only combi boiler KWB..-3A)
- 15.1.3 Plate type heat exchanger (only combi boiler KWB..-3A)
- 15.1.4 Checking the electrodes
- 15.1.5 Burner servicing
- 15.1.6 Heat exchanger block inspection and cleaning
- 15.1.7 Condensate trap cleaning
- 15.1.8 Checking the mixer diaphragm
- 15.1.9 Expansion vessel
- 15.1.10 Setting the boiler water pressure
- 15.1.11 Testing system water quality
- 15.1.12 Inspecting electrical wiring
- 15.2 Checklist for annual inspection and maintenance
- 16 Readings on the display
- 17 Faults
- 18 Commissioning log for the appliance
- 19 Spare parts
- Index
64 | Flue gas test
Greenstar FS
6 720 810 590 (2015/05)
12.4 Dynamic gas pressure test
▶ Switch the appliance OFF and close the gas shut-off valve.
▶ Loosen the screw in the test port for gas inlet pressure
( Fig. 74, [1]) and connect a pressure gauge ( Fig. 75).
Fig. 75 Dynamic gas pressure test port
▶ Turn on the gas cock and switch the appliance ON.
▶ Press and hold the emissions test button until it lights up.
The display shows the supply temperature alternating with =
maximum set output in heating mode.
▶ Briefly press the emissions test button .
The display shows the supply temperature in alternation with =
maximum nominal output.
▶ Check the required inlet gas pressure according to table 23.
▶ Press the emissions test button until the light goes out.
The display returns to the supply temperature.
▶ Switch the appliance OFF, turn off the gas cock, remove the pressure
gauge and tighten the screw in the test port for gas inlet pressure.
▶ Reinstall the cover.
13 Flue gas test
13.1 Emissions test button
The following appliance outputs can be selected by pressing the
emissions test button until it lights up:
Fig. 76 Press the emissions test button
• = Maximum set output in heating mode (à Maximum heating
output, page 57)
• = Maximum nominal output
• = Minimum nominal output
13.2 Measuring CO content of flue gas
Use a multiport flue gas probe for the measurements.
▶ Open one of the flue gas test ports ( Fig. 71).
▶ Insert the flue gas probe approx. 2-3/4 inches (70 mm) into the test
port and seal around it.
▶ Press the emissions test button to select = maximum nominal
output.
▶ Measure the CO levels.
▶ Repeatedly press the emissions test button until the light goes
out.
The display returns to the supply temperature.
▶ Remove flue gas probe and close the flue gas test port properly.
Gas type
Nominal
pressure
" W.C. (mbar)
Permissible pressure range
for maximum nominal output
" W.C. (mbar)
NG 7 (17.4) 3.5-10.5 (8.7-26.1)
LPG (propane) 11 (27.4) 8-13 (19.9-32.3)
Table 23 Inlet gas pressure
Do not operate the appliance if the measured value is
below or above these values. Determine the cause and
eliminate the fault. If this is not possible, block the
appliance on the gas side and notify the gas supplier.
6 720 614 090-34.2O
You have 15 minutes to complete the tests. After that,
the appliance returns to default mode.
DANGER: Risk of flue gas poisoning.
The CO level in the flue gas must be below 200 ppm (air
free).
▶ If 9.4 Vol.%
1)
CO
2
and a CO level under 200 ppm (af)
can not be achieved due to the gas supplied, use a
lower CO
2
level with CO emissions under 200 ppm
(af) instead.
1) 9.4 Vol.% with NG and 11.0 Vol.% with LPG (propane)
max
1
2
34
5
6
eco
reset
6 720 641 933-51.1O
max
1
2
3
4
e
6
min