LTC 1271 Series Instruction Manual EN Corner Mount
SAFETY PRECAUTIONS CAUTION:TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This label may appear on the bottom of the unit due to space limitations.
SECURITE DANGER: POUR ÉVITER TOUT RISQUE D'ÉLECTROCUTION, NE PAS OUVRIR LE BOÎTIER. IL N'Y A PAS DE PIÈCES REMPLAÇABLES À L'INTÉRIEUR. POUR TOUTE RÉVISION, S'ADRESSER À UN TECHNICIEN SPÉCIALISÉ. En raison de limitation de place, cette étiquette peut être placée sur le dessous de l'appareil. L'éclair fléché dans un triangle équilatéral, avertit l'utilisateur de la présence d'une "tension dangereuse" non isolée à l'intérieur de l'appareil et d'une valeur suffisante pour constituer un risque d'électrocution.
SICHERHEITSVORKEHRUNGEN VORSICHT: UM EINEN ELEKTRISCHEN SCHLAG ZU VERMEIDEN, ABDECKUNG NICHT ENTFERNEN.WARTUNGEN ALLER ART QUALIFIZIERTEM PERSONAL ÜBERLASSEN. Aus Platzgründen kann diese Warnung auf der Unterseite des Gerätes angebracht sein. Das Blitzsymbol im gleichseitigen Dreieck soll den Benutzer auf nicht isolierte "Hochspannung" im Gehäuse aufmerksam machen, die eventuell stark genug ist, um einen elektrischen Schlag zu verursachen.
PRECAUCIONES DE SEGURIDAD PRECAUCION: PARA REDUCIR EL RIESGO DE CHOQUE ELÉCTRICO, FAVOR NO ABRIR LA CUBIERTA. ESTE EQUIPO NO CONSTA DE PIEZAS O PARTES QUE REQUIEREN SERVICIO O MANTENIMIENTO. PARA REPARACIONES FAVOR REFERIRSE A UN TÉCNICO CALIFICADO. Debido a limitaciones de espacio, esta etiqueta puede aparecer en la parte inferior de la unidad.
FCC & ICES INFORMATION (U.S.A. and Canadian Models Only) WARNING - This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules and ICES-003 of Industry Canada.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
3. DESCRIPTION & SPECIFICATIONS The LTC 127x Series Corner Phortress units are small, high security surveillance cameras for corner applications. ELECTRICAL Model No. Description Voltage Range Power LTC 1271/10C Color, varifocal 21 to 27 VAC, 50 Hz or 11 to 13 VDC 3.0 W LTC 1271/10CS Color, varifocal 21 to 27 VAC, 50 Hz or 11 to 13 VDC 3.0 W LTC 1271/10CF Color Varifocal 21 to 27 VAC, 50Hz 6.6W LTC 1271/10CSF Color Varifocal 21 to 27 VAC, 50Hz 6.
4. Decide which conduit hole will be used and plug remaining openings using the 2 plugs provided in the hardware kit.The conduit plug on top of the unit may be secured by tightening the set screw at the back of the rear cover. This must be done before the back cover is secured to the wall. Use a 2.5 mm Hex Key (not supplied). 5. Drill hole for conduit and run wiring. 6. Use 6 mm (1/4-inch) bolts with appropriate anchors for the type of wall construction.
5. CAMERA AND LENS SETTINGS Camera module has various settings for any additional adjustments that may be required. See figure 4 and 5 for adjustment locations. 5.1 Phase Adjust The phase adjust control is located on the power board next to power cable connections (see figure 4).To adjust phase, use a small screwdriver to rotate control (blue block with yellow screw hole) until picture is synchronized with other cameras in the system. Phase Adjust Pot on Power Board Figure 4 Camera Assembly 5.
DETAIL B The following chart diagrams the selectable dip switches and their respective functions: Color Camera IRIS FL BLC Sync 1 DC ON ON INT 2 3 1 Note: 2 3 DC IRIS Flickerless (FL) Backlight Compensation (BLC) 4 4 is factory set up Synchronization Mode DC IRIS AES AES ON Shutter speed to be fixed at 1/100 sec. OFF Normal position Set to this position when a strong light is in the back ground. OFF Normal position ON INT Internal Synchronization mode L.L.
6. FIBER OPTIC CONNECTION For Fiber Optic Models, Avoid Tight Bends in the Fiber Cable. Connect Camera and Fiber Module to the same 24VAC Power Source Note Position of Dip Switches for Camera-up-Position. Fiber Optic Connection. Suggested Cable Routing. 7. REPLACEMENT PARTS Part no.
8. DIMENSIONAL OUTLINE 3/4" THREADED CONDUIT OPENING 1 OF 3 TWO PLUGS SUPPLIED. 66.7 [ 2.63 ] HOLE LOCATION BOTH SIDES 90∞ 50.8 [ 2.00 ] CONDUIT HOLE LOCATION, TYPICAL BOTH SIDES. 173.5 [ 6.83 ] 20.3 [ .80 ] 122.7 [ 4.83 ] DIMENSIONS ARE MM [INCHES] 171.3 [ 6.74 ] 83.6 [ 3.29 ] 41.9 [ 1.65 ] 177.1 [ 6.97 ] 92.1 [ 3.63 ] 99.31 [ 3.910 ] ÿ 7.11 [ .280 ] TWO HOLES EACH SIDE. CLOSURE SECURED WITH TAMPER RESISTANT SCREW, DRIVER BIT SUPPLIED. Bosch Security Systems, Inc.