9 ERROR MESSAGES
Error Description Error Description
Error 01 -
Invalid camera request
The camera number entered from the
keyboard does not exist. If using the
LTC 8059/00 MCS or the LTC 8850/00
GUI software, ensure that the number
exists in the Camera Identification table.
Download the table to be sure.
Error 20 -
Acknowledge denied
ACKNOWLEDGE has been
pressed by a user without authority
to acknowledge alarms.
Error 02 -
Invalid monitor request
The monitor number entered from the
keyboard does not exist. Enter a valid
monitor number.
Error 21 -
Incorrect acknowledge
To properly acknowledge an alarm
event, the keyboard must be
switched to a monitor that is
displaying the alarms.
Error 03 -
Locked remote device
The remote device requested cannot be
controlled because it is locked by a user
with equal or higher priority. Check with
the other users or request that a higher
priority user unlock the remote device.
Error 22 -
Acknowledge disabled
Alarms on this monitor cannot be
acknowledged because that
capability has been disabled by the
system programmer.
Error 04 -
Monitor locked
The monitor requested cannot be accessed
because it is locked by a user with equal or
higher priority. Check with the other users
or request that a higher priority user
unlock the monitor.
Error 23 -
Camera not in alarm
The camera displayed on the
monitor is not an alarm video;
only alarm-generated video can be
acknowledged.
Error 05 -
Remote device
access restricted
Remote is locked out by Remote Lock Out
table.
Error 24 -
Keyboard not enabled for
acknowledge
This keyboard may not
acknowledge alarm video on this
monitor; it has been disabled by
the system programmer.
Error 06 -
Monitor access
restricted
Monitor is locked out by Monitor Lock
Out Table.
Error 25 -
Alarm switcher running
Alarm video may only be
acknowledged if the alarm switcher
is not running; press HOLD to
stop the switcher.
Error 10 -
Access denied
A function was requested that requires a
higher user priority. Only a priority 2 user
or a supervisor with priority 1 may access
this function.
Error 50 -
SEQUENCE not available
Error 51 -
SEQUENCE not available
The user tried to load a switcher
sequence that does not exist. This
is a good way to tell from the
keyboard, which sequence
numbers are unused when desiring
to add one.
A request was made to load an
ABSOLUTE sequence without the
keyboard being on one of the
monitors in that sequence. Because
inadvertent loading of monitors
should be avoided, the user is
required to switch his keyboard to
one of the monitors used by the
sequence. The PROGRAM mode
may be used to review which
monitors are used in the sequence.
Error 11 -
Access denied
A function was requested for which your
user priority is too low. Only a supervisor
with priority 1 may access this function.
Error 52 -
SEQUENCE request
A request was made to load a
RELATIVE sequence on a
monitor number that is too high.
The monitors used by the sequence
would extend past the highest
monitor. Try switching to a lower
monitor number before loading the
sequence.
Error 15 -
Invalid user function
The function number requested from the
keyboard is invalid. Refer to the User
Function table for a listing of the valid user
function numbers.
Error 53 -
Switcher empty
The user has tried to control a
sequence using NEXT, PREV,
RUN, or HOLD without a
sequence having been loaded.