Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
CPU and Data Receiver LED Indicators:
PCB ID PCB Label Color Function
D1000 RESET Red Lit during reset condition
D0908 CPU ACT. Green Flashes to indicate processor activity
D0909 BATT LOW Red Lit when battery is low
D1001 Temp CRIT Green Lit when temperature is critical
D0800 LAN LINK/ACT Green Lit indicates network condition; Flashing at packet rate indicates activity
D0801 LAN 100BASET Red Lit indicates 100BaseT connection
D0802 LAN DUP/COL Yellow Lit indicates duplex mode; Flashing at paced rate indicates collisions
D0500 SDU ACT Green Flashes at Biphase data packet rate
D0701 CONSOLE Green Lit when RS-232 connection exists
D0702 PRINTER Green Lit when RS-232 connection exists
D0700 ALARM Green Lit when RS-232 connection exists
D0900 LED1 Red Lit when flash memory is getting updates
D0901 LED2 Green No function
D0902 LED3 Yellow No function
D0903 LED4 Red No function
D0904 LED5 Green No function
D0905 LED6 Yellow No function
D0906 LED7 Red No function
D0907 LED8 Green Flashing indicates keyboard polling activity
Table 9.3: LED Indicators
102 en | Troubleshooting Guide LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.