Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
NOTE: The LTC 8902 Series and LTC 8903 Series bays should be installed so there is at least
4.5 cm (1-3/4 in.) of clearance above and below the bay, to allow for proper cooling. Failure to
provide proper clearance may cause the equipment to exceed its recommended operating
temperature range.
DO NOT install the LTC 8934/00 Video Output modules or the LTC 8921/00 Video Input
modules into the matrix bays at this time.
Module Insertion
A special tool is supplied with the system components, for insertion of the Data Receiver,
Video Input Module, and Video Output Module boards into LTC 8902 and LTC 8903 Series
equipment bays. The tool is a simple lever (an angled piece of aluminum), used as follows:
Insert the board fully into the slot, ensuring proper alignment with the connectors. Insert the
short end of the lever into the groove in the front of the bay so the tool is aligned with the
card ejectors on the card, then push the lever to force the card into the slot.
IN S R -T O L
Figure 5.4: Example of Insertion Tool Use
Data Receiver Modules
LTC 8902 Series Video Output bays are supplied with LTC 8916/01 Data Receiver modules.
LTC 8903 Series Video Input bays are supplied with LTC 8918/01 Data Receiver modules. Data
Receiver Modules are installed into the right most slot (adjacent to the power supply) of the
matrix bays as shown below:
Figure 5.5: Typical Data Receiver Module Insertion
LTC 8916/01 Data Receiver Modules
The LTC 8916/01 Data Receiver modules (installed in LTC 8902 Series bays) contain three (3)
8-position dip switches.
5.5
5.6
5.7
24
en | Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series
CPU
LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.