For system configurations of up to 2048 cameras and 512 monitors, , page 68 can be used as
a guide for setting the Data Receiver DIP switches. Otherwise, follow the procedure described
below.
Verify that switches located on dipswitch S1 and S3 are all OFF.On dipswitch S2 of the LTC
8916/01, verify that switches 1 to 4 are OFF. Switch 8 should be in the ON position. Switches
5 through 7 determine the monitor number range that the bay will be used for and must be set
according to the table below:
5 6 7 Monitor Range
OFF OFF OFF 1 to 64
OFF OFF ON 65 to 128
OFF ON OFF 129 to 192
OFF ON ON 193 to 256
ON OFF OFF 257 to 320
ON OFF ON 321 to 384
ON ON OFF 385 to 448
ON ON ON 449 to 512
Table 5.1: LTC 8916/01 Data Receiver Module Switch Positions (used in LTC 8902 Service Bays)
LTC 8918/01 Data Receiver Modules
The LTC 8918/01 Data Receiver modules (installed in LTC 8903 Series bays) contain three (3)
8-position dip switches. For system configurations of up to 2048 cameras and 512 monitors, ,
page 68 can be used as a guide for setting the Data Receiver DIP switches. Otherwise, follow
the procedure described below.
Verify that switches 1 to 3 and 5 to 8 on dipswitch S1 are OFF.
If the LTC 8903 Series bay will be used as a primary camera bay (one that will have cameras
directly connected to it), place switch 4 on S1 in the OFF position.
If the LTC 8903 Series bay will be used as a secondary camera bay (one that will have other
LTC 8903 Series bays connected to its inputs), place switch 4 on S1 in the ON position.
If switch 4 on S1 has been set to the OFF position (for use as a primary camera bay as
described previously), set switches 1 to 4 on S2 according to the Primary Camera Bay Range
in , page 25 shown below:
1
2 3 4 Camera Number Range
OFF OFF OFF OFF 1 to 256
OFF OFF OFF ON 257 to 512
OFF OFF ON OFF 513 to 768
OFF OFF ON ON 769 to 1024
OFF ON OFF OFF 1025 to 1280
OFF ON OFF ON 1281 to 1536
OFF ON ON OFF 1537 to 1792
OFF ON ON ON 1793 to 2048
5.8
LTC 8900 Series