Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
Monitors 33-64Monitors 1-32
Cameras 1-256
Monitor Outputs 1-32
Logical Monitor Numbers 1-32
Monitor Outputs 65-96
Logical Monitor Numbers 33-64
LTC 8902 Monitor Bay
LTC 8903 Camera Bay
LTC 8902 Monitor Bay
LTC 8903 Camera Bay
Figure 6.4: Fault-tolerant 256 Camera x 64 Monitor System
3. If possible, rack the LTC 8902 Series bays so they are in a central location with respect to
the LTC 8903 Series bays. This is especially important in large system configurations
where many LTC 8903 Series Input Bays will be feeding video to a single or a few LTC
8902 Series Output Bays.
NOTE: Interconnecting LTC 8902 Series bays and LTC 8903 Series bays must be located
close enough together that the supplied 2 m (6 ft) video interconnect cables can be used.
Although not a requirement, the matrix bay video interconnect cabling will be easier to
manage if the LTC 8902 Series Bays are mounted higher up in the rack, above any LTC
8903 Series Input Bays.
4. Camera and monitor video connections are NOT made directly to the LTC 8902 Series
and LTC 8903 Series matrix bays. All external video connections are made to LTC
8808/00 Video Interconnect Panels. Each LTC 8808/00 panel accepts up to 32 video
connections and interfaces to the various matrix bays using two (2) LTC 8809/00 video
ribbon cables. The LTC 8808/00 panels can be mounted wherever convenient, as long as
they are within 2 m (6 ft) of the matrix bay that they are being used with 2 m (6 ft) length
of the LTC 8809/00 ribbon cable).
38
en | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC
8901 Series CPU
LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.