Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
P rima ry
Ba ck -U p
P ow er
In U s e
C PU A ctiv ity
Fa u lt
C on trolle r A c tivity
Au to
P rima ry C P U
Ba ck -U p C P U
P ow er
In U s e
C PU A ctiv ity
Fa u lt
A L L EG IA N T M a trix C P U
BOSCH
Figure 6.6: LTC 8901 Series CPU Bay
It is recommended that the CPU bay be mounted so a 9 cm (3-1/2 in.) rack space is
available either above or below the enclosure. In sites where the system can not be taken
out of operation for a period of time, this will leave a mounting space available for a
replacement CPU in the unlikely event that the original CPU must be removed for servicing.
Verify that the front panel selector switch is set to AUTO.
Do not attach line cord to AC power source until instructed to do so.
LAN Switch Installation
The LTC 8944/93, LTC 8945/93, and LTC 8946/93 are 10/100Base-T LAN switches. The LTC
8944/93 and LTC 8945/93 LAN switches are used in redundant system configurations only.
Disregard the original manufacturer s instructions supplied with the LAN switches.
All three models of LAN switches are standard 10/100Base-T network switches supplied with
software (on CD-ROM) and network installation instructions by the original manufacturer. The
software supplied with the switches is not used. The switches for the LTC 8900 systems are
used in a network dedicated to only the LTC 8900 system. The switches must not be
connected to a computer network, or any other network. To use the switches in the LTC 8900
system, follow the directions in this manual ONLY.
All data cables going to the switches connect to the front panel ports. The main AC line cord is
connected to the rear panel of the switch. If desired, the switches can be mounted so that the
front panel is facing into the rack. Determine which orientation is most suitable for your
application, then attach the supplied racking ears to the side mounting holes accordingly.
Attach AC line cords to switches, but do not attach line cord to AC power source until
instructed.
LTC 8943/95 System Controller PC Installation
PC Installation
The LTC 8943/95 PC is supplied with all internal modules fully assembled. The rack ears can
be attached or removed depending on if the unit will be installed into an EIA 19 in. rack or
placed on desktop surface. Attach AC line cord but do not attach line cord to AC power source
until instructed.
6.3
6.4
6.4.1
40
en | Hardware Installation Procedure for Redundant System Configuration Utilizing LTC
8901 Series CPU
LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.