Installation Manual

Table Of Contents
1 2 3 4 Camera Number Range
ON ON ON OFF 3585 to 3840
ON ON ON ON 3841 to 4096
Table 6.2: LTC 8918/01 Data Receiver Module (used in LTC 8903 Series bays) S2 positions 1 through 4
LTC 8903 Series Camera bays always provide video signals (either directly, or via a second
LTC 8903 Series bay) to a specific LTC 8902 Series Monitor bay. Determine the applicable
LTC 8902 Series Monitor bay, then set switches 5 through 7 on dip switch S2 to the same
settings as switches 5 through 7 on S2 of the Data Receiver module installed in the
corresponding LTC 8902 Series bay. These will be the same settings as listed in the Monitor
Number Range shown in , page 43.
ON dip switch S2 of the LTC 8918, verify that switch 8 is ON.
If switch 4 on S1 has been set to the ON position (for use as a secondary camera bay as
described above) set switches 3 and 4 of S2 OFF and set switches 1 and 2 of S2 according to
which primary camera bays it will be connected to per , page 44.
1
2 Primary Camera Bay Range
OFF OFF 1 to 4
OFF ON 5 to 8
ON OFF 9 to 12
ON ON 13 to 16
Table 6.3: LTC 8918 Data Receiver Module (used in LTC 8903 bays) S2 Positions 1 and 2
LTC 8934/00 Video Output Modules
The appropriate number of LTC 8934/00 Video Output Modules should be installed in the LTC
8902 Series main bay starting with the left most slot. Each output module handles 8 outputs.
If fewer than the maximum number of Video Output Modules are installed, they should be
installed from left to right, with empty spaces on the right.
In some system configurations, 8 or less LTC 8934/00 modules may be distributed between
two (2) LTC 8902 Series Video Output bays. This configuration assures partial system
operation in the unlikely event of an LTC 8902 Series failure. Since this creates a gap in the
monitor number order, the system software allows renumbering of the logical monitor
numbers. For example, if the system was designed for 64 monitor outputs, four LTC 8934/00
modules (handling monitors 1 to 32) would be installed in the first LTC 8902 Series bay.
Another four LTC 8934/00 modules would be installed in a second LTC 8902 Series bay.
The default monitor number range for this second module would be 65 to 96. Since this would
be inconvenient to operators of the system, the logical numbers of the monitor numbers in the
second bay can be renumbered to range from 33 to 64 using the software on the System
Supervisor PC. , page 37 shows an example of this type of configuration. It is also possible to
number the monitors so that one bay contains the odd numbered monitors and the other bay
contains even numbered monitors. This way, a viewing location containing an even mix of
monitors from each bay would lose every other one in the unlikely event of an LTC 8902 Series
bay failure.
6.10
LTC 8900 Series
Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901
Series CPU | en
45
Bosch Security Systems, Inc. Installation Manual 2016.04 | 10.7 | F.01U.323.096