Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
"A "
1234123412341234
"B""C "
"D "
"A "
1234123412341234
"B""C "
"D "
LT C 8903
09
LTC 8902
Lower
LTC 8809
Ribbon
Cable
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
Front View -- Module Placement and Termination Settings
LTC 8902
LTC 8903–
Cameras 1–256
Rear View – LTC 8809 Interconnect Cable Routing
8 LTC 8921 Video Input
Modules Installed in Odd
Numbered Slots only are
Required for Camera Inputs
1 to 256
All Termination Switches
are Set to ON Position on all
LTC 8921 Video Input Modules
4 LTC 8934 Video Output
Modules installed in First
4 Slots are Required for
Monitors 1 to 32. Set all
Termination Switches to ON
Position on all Modules
LTC 8902
To
“A1”
To
“A1”
To “D1”
To
“A2”
To
“B1”
To
“B2”
“B2”
“B1”
“C1”
“A2”
“C2”
“D2”
To Video
In “A”
To Video In “A”
To Video
In “B”
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
To Video
In “A”
To Video
In “B”
To Video
In “B”
To Video
In “A”
To Video
In “B”
2 LTC 8809 Cables are Required for
32-channel Video Bus to LTC 8902
Module, Termination, and Interconnect Cabling for 512 Camera by 32 Monitor System
8 LTC 8921 Video Input
Modules Installed in
Odd Numbered Slots only
are Required for Camera
Inputs 257 to 512
LTC 8903–
Cameras 257–512
LTC 8903
LTC 8903
LTC 8903
LTC 8902
LTC 8903
8 LTC 8808 Panels
are Required for Camera
Inputs 257 to 512
8 LTC 8808 Panels are Required
for Camera Inputs 257 to 512
2 LTC 8809 Cables
are Required for 32-channel
Video Bus to LTC 8902
4 LTC 8809
Cables are Required
for 64-channel
Video Bus to
LTC 8902
4 LTC 8809 Cables
are Required for 64-channel
Video Bus to the LTC 8902
8 LTC 8808
Panels are Required
for Camera Inputs
1 to 256
8 LTC 8808
Panels are Required
for Camera Inputs
1 to 256
Front View – Module Placement and Termination Settings
Rear View – LTC 8809 Interconnect Cable Routing
Monitors 33–64
Monitors 1–32
16 LTC 8921 Video
Input Modules are Required
for camera inputs 1 to 256
16 LTC 8921 Video
Input Modules are Required
for Camera Inputs 257 to 512
8 LTC 8934 Video Output Modules
are Required for Monitors 1 to 64.
Set all Termination Switches to ON
Position on all Modules.
Module, Termination, and Interconnect Cabling for 512 Camera by 64 Monitor System
LTC 8903–
Cameras 257–512
LTC 8903–
Cameras 1–256
Set LTC 8921 Module
Termination Switches
in ODD Numbered Slots
to OFF (both LTC 8903 Bays)
Set the LTC 8921 Module Termination Switches
in EVEN Numbered Slots to ON (both LTC 8903 Bays)
Figure 8.30: Module, Termination, and Interconnect Cabling for 512 Camera by 32 or 64 Monitor System
86
en | Satellite System Configuration Installations LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.