Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
"A "
123
4
1
23
4123412
34
"B "
"C "
"D "
o
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
To
“A1”
To “D1”
“B2”
“B1”
“C1”
“A2”
“C2”
“D3”
“D2”
“C3”
“B3”
“A3”
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
To Video
In “A”
To Video
In “B”
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
To Video
In “A”
To Video
In “B”
To Video
In “A”
To Video
In “B”
LTC 8903
LTC 8903
LTC 8903
LTC 8902
8 LTC 8808 Panels are Required
for Camera Inputs 257 to 512
16 LTC 8921 Video Input
Modules are Required for
Camera Inputs 1 to 256
8 LTC 8934 Video Onput Modules are
Required for Monitors 1 to 64.
Set all Termination Switches to
ON for all Modules.
16 LTC 8921 Video Input
Modules are Required for
Camera Inputs 257 to 512
16 LTC 8921 Video Input
Modules are Required for
Camera Inputs 513 to 768
8 LTC 8808 Panels are Required
for Camera Inputs 513 to 768
4 LTC 8809
Cables are Required
for 64-channel
Video Bus to
LTC 8902
4 LTC 8809 Cables
are Required for 64-channel
Video Bus to LTC 8902
8 LTC 8808
Panels are Required
for Camera Inputs
1 to 256
Monitors 33–64
Monitors 1–32
LTC 8903–
Cameras 257–512
LTC 8903–
Cameras 1–256
LTC 8902
LTC 8903–
Cameras 513–768
Set LTC 8921 Module Termination
Switches in ODD Numbered Slots
to OFF (all LTC 8902 Bays)
Set LTC 8921 Module Termination
Switches in EVEN Numbered Slots to
ON (all LTC 8903 Bays)
Front View – Module Placement and Termination Settings
Rear View – LTC 8809 Interconnect Cable Routing
Figure 8.31: Module, Termination, and Interconnect Cabling for 768 Cameras by 64 Monitors
LTC 8900 Series Satellite System Configuration Installations | en 87
Bosch Security Systems, Inc. Installation Manual 2016.04 | 10.7 | F.01U.323.096