Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
"A "
1234123412341234
"B "
"C "
"D "
"
"D 1"
"C 1"
"B 1"
"A 1"
Each Line
Represents an
LTC 8809
Ribbon
Cable
Each Line
Represents an
LTC 8809
Ribbon
Cable
“Secondary” LTC 8903
Camera Bay Containing
8 LTC 8921 Video
Input Modules
“Secondary” LTC 8903
Camera Bay Containing
8 LTC 8921 Video
Input Modules
LTC 8902
Monitor Bay
Containing
Modules for
64 Monitor
Outputs
Group Inputs 3 and 4 are
used for additional LTC 8903
Camera Bay Connections
Rear View – LTC 8809 Interconnect Cable Routing
8 LTC 8808 Panels are Required
for Camera Inputs 1 to 256
“Primary” LTC 8903 Bay
Cameras 257–512
“Primary” LTC 8903 Bay
Cameras 1–256
“Primary” LTC 8903 Bay
Cameras 513–768
“Primary” LTC 8903 Bay
Cameras 769–1024
“Primary” LTC 8903 Bay
Cameras 1281–1536
“Primary” LTC 8903 Bay
Cameras 1025–1280
“Primary” LTC 8903 Bay
Cameras 1537–1792
“Primary” LTC 8903 Bay
Cameras 1793–2048
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
To Video
In “A”
To Video
In “B”
Lower
LTC 8809
Ribbon
Cable
Upper
LTC 8809
Ribbon
Cable
Monitors 33–64
Monitors 1–32
“D”
“C” “B”
“A”
“D” “C”
“B”
“A”
“D” “C”
“B” “A”
“D”
“C” “B”
“A” “D” “C” “B” “A”
“D”
“D2”
“C2”
“B2”
“A2”
D
C
B
A
“C” “B” “A”
“D”
“C”
“B”
“A”
“D”
“C”
“B”
“A”
“D”
“C”
“B” “A”
Figure 8.36: Interconnect Cabling for 2048 Camera by 64 Monitor System
92 en | Satellite System Configuration Installations LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.