Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Safety
- Unpacking
- Introduction
- System Components
- LTC 8904 Series CPU Bay
- LTC 8901 Series CPU Bay
- LTC 8902 Series Output Bay
- LTC 8903 Series Input Bay
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- LTC 8943/95 System Controller PC
- LTC 8944/93 and LTC 8945/93 LAN Switches
- LTC 8946/93 LAN Switches
- LTC 8809/00 Video Ribbon Cable
- LTC 8808/00 Video Interconnect Panel
- LAN Cables
- Security Key for PC-based Software
- Miscellaneous Components
- Hardware Installation Procedure for Standard Systems Utilizing LTC 8904 Series CPU
- General Installation Considerations
- LTC 8904 Series CPU Bay Installation
- LAN Switch Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- Hardware Installation Procedure for Redundant System Configuration Utilizing LTC 8901 Series CPU
- System Redundancy Considerations
- Main CPU Bay Installation
- LAN Switch Installation
- LTC 8943/95 System Controller PC Installation
- LTC 8902 Series Output Bay and LTC 8903 Series Input Bay Installation
- Module Insertion
- Data Receiver Modules
- LTC 8916/01 Data Receiver Modules
- LTC 8918/01 Data Receiver Modules
- LTC 8934/00 Video Output Modules
- LTC 8921/00 Video Input Modules
- System Video Connections
- Termination Practices
- System Data Connections
- Main Power Connections
- LTC 8901 Series CPU Relay Outputs and Buzzers
- LTC 8901 Series CPU Selection Switch
- Camera Phasing and Accessory Installation
- Satellite System Configuration Installations
- Allegiant Satellite System Configuration Installations
- Satellite Site “Trunk Line” Monitor Outputs
- Main Site “Trunk Line” Video Inputs
- Control Data Lines in Satellite Systems
- Satellite Sites Programming Requirements
- Main Site Programming Requirements
- Special Programming for “Cascaded” Satellite System Configurations
- Alarm Inputs in Satellite Systems
- Troubleshooting Guide
- Maintenance Information
- Pinouts
- Back Page
Set all LTC 8921 Module
Termination Switches Inside
“Primary” First Level
LTC 8903 Bays to OFF
System Cameras Connect to “Primary” First Level LTC 8903 Bays
Video Interconnect
LTC 8809 Cables
Video Interconnect
LTC 8809 Cables
Video Interconnect
LTC 8809 Cables
Video Interconnect
LTC 8809 Cables
8 LTC 8934 Video
Output Modules
are Required for
Monitors 1 to 64.
Set all Termination
Switches to ON
for all Modules.
4 LTC 8934 Video
Output Modules
are Required for
Monitors 65 to 96.
Set all Termination
Switches to ON
for all Modules.
Set all Termination
Switches on the LTC 8921
in “Secondary” LTC 8921
Bays to ON
4 LTC 8921 Video
Input Modules
(in slots 1, 5, 9,
and 13) are Required
LTC 8902 for
Monitors 65 to 96
LTC 8902 for
Monitors 1 to 64
Set all Termination
Switches on the LTC 8921
Modules in Secondary
LTC 8921 Bays to ON
8 LTC 8921 Video
Input Modules
(in Slots 1, 4, 5, 8, 9,
12, 13, and 16) are Required
Install the LTC 8921 Modules
in ODD Numbered Slots
only in Second Level “Primary”
Bays. Set all Termination
Switches to ON.
Only 8 LTC 8921
Video Input Modules
are Required in the
Second Level Bays
because the Second
level LTC 8902 Output
Bay Supports only
32 Monitors
LTC 8809 Cables
Loop Video to
Second Level
Primary Bays
Cameras
257–512
Cameras
1–256
Cameras
513–768
Cameras
769–1024
Cameras
1281–1536
Cameras
1025–1280
Cameras
1537–1792
Cameras
1793–2048
“Secondary” Level LTC 8903 Bay
(for Camera Range 1025 to 2048)
“Secondary” Level LTC 8903 Bay
(for Camera Range 1025 to 2048)
“Secondary” Level LTC 8903 Bay
(for Camera Range 1 to 1024)
“Secondary” Level LTC 8903 Bay
(for Camera Range 1 to 1024)
98 en | Satellite System Configuration Installations LTC 8900 Series
2016.04 | 10.7 | F.01U.323.096 Installation Manual Bosch Security Systems, Inc.