Spec Sheet

Alarm control Rules-based logic supports basic and complex pre-
defined user-specified commands
In its most basic form, a “rule” could define which
input(s) should activate which output(s).
Washer Pump
Interface
Control functions integrated. Alarm/Washer
Interface Unit (MIC-ALM-WAS-24, sold separately)
provides electrical interface to user supplied
washer pump device.
Camera status
monitoring
Integrated sensors monitor operational status such
as internal temperature, humidity level, incoming
voltage level, vibration, and shock events.
Diagnostics Various status conditions are tracked in internal
diagnostic log. Critical fault conditions will also be
displayed on screen.
Supported
mounting
options (with
applicable
accessories)
Direct to a surface
On a wall (Cables through the wall)
On a wall (Conduit/cables down the wall)
On the corner of a wall
On a pole
Mechanical
Drive Unit Brushless, integral pan/tilt motor drive
Supported
mounting
orientation
Upright
Inverted
Pan Range 360° continuous rotation
Tilt Angle 292°
Tilt Range Upright unit: -56° to +90°
Inverted unit: -90° to +56°
Variable Pan Speed 0.2°/second to 120°/second
Variable Tilt Speed 0.2°/second to 90°/second
Intelligent Tracking
Speed
4°/second to 120°/second
Pre-position Speed Maximum 120°/second, with no more than 2.5
seconds to reach new position (excluding time
to zoom and focus at new position)
Preposition
Accuracy
0.05° (typical)
Proportional Pan /
Tilt to Zoom
Yes
Audible Noise <65 dB
Electrical
Input Voltage
21-30 VAC, 50/60 Hz, and/or High Power
over Ethernet 56VDC nominal
Current
Consumption
4.0A (24 VAC)
1.5A (High PoE)
Power Consumption
(typical) (Includes
integrated heater,
defroster, and fan)
72W (24 VAC)
72W (High PoE)
High PoE 95W High Power over Ethernet (Requires
NPD-9501A midspan from Bosch (sold
separately).)
56VDC
Redundant
configuration
Connect both High PoE Midspan and a
separate 24 VAC power source. If either the
High PoE or 24 VAC power source fails, the
camera seamlessly transitions over to use the
remaining power source.
Surge protection Built-in surge protection for power, data, and
network interfaces
Communications / Software Control
Camera Setup/
Control
Via Internet Explorer web browser version 7.0
or later, Bosch Configuration Manager, Bosch
Video Management System (BVMS), Bosch
Video Security Client (VSC), or support for
third party software
Supported Serial
Protocols
Bosch OSRD, Pelco D/P, Forward Vision,
Cohu. Requires separate eLicense installation.
Cloud-based
services
Time-based or alarm-based JPEG posting to
four different accounts. Accounts can address
FTP servers or cloud-based storage facilities.
Alarm events can be set up to trigger an e-mail
or SMS notification.
Firmware upload Completed over network using built-in web
browser or from Bosch Configuration Manager
User Connections
Accessory Interface/
Control Data
RS-485, Simplex, half and full duplex, user-
selectable baud rate or auto-baud
Used to communicate with optional Alarm/
washer interface box (MIC-ALM-WAS-24) or
with Bosch OSRD, Pelco P/D, Forward Vision,
and Cohu serial protocols.
Power, network Ethernet High PoE (95 W)
RJ45 10/100Base-Tx, male connector;
Female-to-female RJ45 coupler included
Power, pigtail 24 VAC (nominal)
Chassis ground Ground wire with connector lug
Audio
Compression
G.711, AAC, and L16 (live and recording)
Signal-to-Noise Ratio
(SNR)
Audio-in: 47 dBA (A-weighting)
Audio out: 50 dBA (A-weighting)
9 | MIC IP fusion 9000i