3.3 MIC Power Supply Units (PSUs) for Non-IR MIC Cameras
The figure below displays the layout of the PCB in the MIC PSUs for non-IR cameras, with call-
out numbers to the side of or below the connection/terminal ID or the terminal, and ’on’ the
fuses. The table below the figure identifies the connections.
Figure 3.3 Layout of PCB in enclosure of PSU for non-IR MIC cameras
Number Connection /
Terminal ID on PCB
Description/Function of
Connection / Terminal
Type of Connection /
Terminal
1 HD1 AC Power input Screw terminal
2 HD3 Shielded composite cable
(analog connections to camera)
Screw terminal
3 HD5 RS-485 control Screw terminal
4 HD4 USB to RS-485 converter Molex connector
5 HD8 **NOT USED** Molex connector
6 HD6 [Optional] Auxiliary, heater Screw terminal
7 HD7 Video (composite cable) Screw terminal
8 HD2 Tamper switch Screw terminal
9 CN3 (Video Switched) Coax connection BNC socket
10 CN1 (Video Out) Coax connection BNC socket
11 CN2 Auxiliary card header Plug in
12 Earth Link Earth Link --
13 FS2 Fuse 2 - Primary protection --
14 FS1 Fuse 1 - MIC camera protection --
15 FS3 Fuse 3 - Heater protection 1 --
16 FS5 Fuse 5 - Heater protection 2 --