User Manual

22 en | Installation MIC Series IP Power Supply
F.01U.265.804 | 1.6 | 2012.08 User Manual Bosch Security Systems, Inc.
23. Make the connections for Alarm inputs as needed.
- For IP connections, connect the lines for the alarm inputs (for external devices such as
door contacts or sensors) to terminals IN1 and IN2 on the orange terminal block (see the
section "Terminal block" in the Appendix of the User Manual) of the encoder, and check
that the connection is secure. Connect each alarm input to a ground contact (GND). With
the appropriate configuration, an alarm sensor can automatically connect the encoder to
a remote location, for example.
Note: You can use a zero potential closing contact or switch as the actuator.
If possible, use a bounce-free contact system as the actuator.
- For physical alarm connections on MIC IR power supplies, connect alarm input cables to
terminal block HD2, as indicated in the table below:
24. Make the connections for Relay outputs as needed. Connect the lines for the relay
outputs (for switching external units such as lamps or alarm sirens) to terminals R1 and
R2 on the orange terminal block of the encoder, and check that the connection is secure.
You can operate these relay outputs manually while there is an active connection to the
encoder. The outputs can also be configured to activate sirens or other alarm units
automatically in response to an alarm signal.
25. To save recordings locally, insert an SD card into the slot SD CARD of the encoder by
carefully sliding the card into the slot as far as it will go, until it locks into place.
(To remove the card, push carefully in the direction of insertion until the mechanical
catch releases, and then remove the card.)
26. On MIC IR power supplies, a washer drive is standard. A 24 VAC rated relay is fitted via the
onboard fuse FS4 (rated at 2.5 Amps). Make the following washer pump connections to
terminal block HD7 (marked Washer Drive on the PCB):
Signal Pin Number
Alarm 1 1
0 V 2
Alarm 2 3
0 V 4
Alarm 3 5
0 V 6
Alarm 4 7
0 V 8
CAUTION!
A maximum load of 30 V
p-p
and 200 mA (SELV) may be applied to the relay contacts.
CAUTION!
If the card is formatted already, all existing data will be deleted from the card! Before
inserting the card, check whether the SD card contains any data that must be backed up.
Signal Pin Number
Washer Pump 1
Washer Pump 2
WARNING!
The washer pump terminal is rated only to 24 VAC or VDC maximum voltage and is not
suitable for Mains-operated pumps.