MIC Series Power Supplies Table of Contents | en 3 Table of Contents 1 Safety 4 1.1 Important safety instructions 4 1.2 Safety precautions 6 1.3 Important notices 1.4 Customer Support and Service 14 7 2 Introduction 16 2.1 Parts List 16 2.2 Preparing the Power Supply Unit 17 2.3 Securing the Power Supply Unit 18 2.4 IP Rating 18 2.5 MIC Shielded Composite Cable Gland Connection 19 3 MIC Non-IR Power Supply Units 20 3.1 Printed Circuit Board Earth Link 20 3.
en | Safety MIC Series Power Supplies 1 Safety 1.1 Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but a moist flufffree cloth or leather shammy may also be used.
MIC Series Power Supplies 8. Safety | en 5 Power supply cord and plug protection - Protect the power supply cord and plug from foot traffic, being pinched by items placed upon or against them at electrical outlets, and its exit from the unit. For units intended to operate with 230 VAC, 50 Hz, the power supply cord must comply with the latest versions of IEC 60227. For units intended to operate with 120 VAC, 60 Hz, the power supply cord must comply with the latest versions of UL 62 and CSA 22.2 No.49.
en | Safety MIC Series Power Supplies 13. Safety check - Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operating condition. 14. Installation - Install in accordance with the manufacturer's instructions and in accordance with applicable local codes. 15. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer.
MIC Series Power Supplies 1.3 Safety | en 7 Important notices Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit may fall, causing serious injury and/or serious damage to the unit. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use caution and care when moving the cart/apparatus combination to avoid injury from tip-over.
en | Safety MIC Series Power Supplies Disposal - Your Bosch product was developed and manufactured with high-quality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material. Separate collecting systems are usually in place for disused electronic and electrical products.
MIC Series Power Supplies Safety | en 9 Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive force or shock may damage the unit and the hard disk drives. Outdoor signals - The installation for outdoor signals, especially regarding clearance from power and lightning conductors and transient protection, must be in accordance with NEC725 and NEC800 (CEC Rule 16-224 and CEC Section 60).
en | Safety MIC Series Power Supplies NOTICE! This is a class B product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. FCC & ICES Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
MIC Series Power Supplies Safety | en 11 INFORMATIONS FCC ET ICES Suite à différents tests, cet appareil s'est révélé conforme aux exigences imposées aux appareils numériques de classe B, en vertu de la section 15 du règlement de la Commission fédérale des communications des États-Unis (FCC), et en vertu de la norme ICES-003 d'Industrie Canada.
en | Safety MIC Series Power Supplies Disclaimer Underwriter Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UL's Standard(s) for Safety for Closed Circuit Television Equipment, UL 2044. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product.
MIC Series Power Supplies Safety | en 13 Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. NOTE! This manual has been compiled with great care and the information it contains has been thoroughly verified. The text was complete and correct at the time of printing. The ongoing development of the products may mean that the content of the user guide can change without notice.
en | Safety 1.4 MIC Series Power Supplies Customer Support and Service If this unit needs service, contact the nearest Bosch Security Systems Service Center for authorization to return and shipping instructions. Service Centers USA Repair CenterTelephone: 800-566-2283 Fax: 800-366-1329 E-mail: repair@us.bosch.com Customer Service Telephone: 888-289-0096 Fax: 585-223-9180 E-mail: security.sales@us.bosch.com Technical Support Telephone: 800-326-1450 Fax: 585-223-3508 or 717-735-6560 E-mail: technical.
MIC Series Power Supplies Safety | en 15 Warranty and more information For additional information and warranty queries, please contact your Bosch Security Systems representative or visit our website at www.boschsecurity.com. Bosch Security Systems, Inc. Installation Manual F.01U.141.598 | 1.0 | 2009.
en | Introduction 2 MIC Series Power Supplies Introduction The MIC Series power supplies from Bosch Security Systems, Inc. provide all connections for power, telemetry and video for the MIC Series range of PTZ cameras. Each power supply has CE and FCC approval and is rated to IP65.
MIC Series Power Supplies – Introduction | en 17 Three (3) M12 cable glands for telemetry, video and ancillary equipment. – One (1) M16 gland for connection of the screened composite cable to the MIC camera. – One (1) 1/2 in. NPT cable gland for the power cable – One (1) 1/2 in. NPT and one (1) M12 blanking plug. connection. 2.2 Preparing the Power Supply Unit – Remove the blanking plug that covers the hole for the power cable and attach the supplied 1/2 in.
en | Introduction 2.3 MIC Series Power Supplies Securing the Power Supply Unit Secure the power supply unit using four (4) M6 screws or bolts (not supplied); which secure through the holes in the enclosure as shown In the figure below. Figure 2.1 1 2 2.4 Enclosure mounting and enclosure lid screw holes Enclosure mounting screw Enclosure lid screw hole IP Rating The power supply enclosure is an IP65 weather-resistant cast aluminium enclosure.
MIC Series Power Supplies 2.5 Introduction | en 19 MIC Shielded Composite Cable Gland Connection The MIC power supplies are designed to use the MIC shielded composite cable. Fit this cable into the M16 nickel plated brass cable gland as detailed below. It is important that the braided cable screen engages with the internal clamps of the cable gland to ensure correct EMC protection. 1. Strip the cable jacket back, leaving 25 mm of braided shield; then fold the braided shield back over the cable jacket.
en | MIC Non-IR Power Supply Units 3 MIC Series Power Supplies MIC Non-IR Power Supply Units Use this chapter to install the following MIC power supply units: – MIC-240PSU-UL – MIC-115PSU-UL – MIC-24PSU-UL The MIC power supplies provide power, telemetry and video connections for a single MIC camera appropriate for the power supply type.
MIC Series Power Supplies MIC Non-IR Power Supply Units | en 21 to be connected to a central earth point. If fiber optics or other indirect connections are used to get data and video to and from the control room then the earth link should be left intact provided it is the only camera end earth reference point. Figure 3.1 Bosch Security Systems, Inc. Position of earth link Installation Manual F.01U.141.598 | 1.0 | 2009.
en | MIC Non-IR Power Supply Units 3.2 MIC Series Power Supplies Non-IR Power Supply Layout and Connections The following figure shows the power supply PCB connections: Figure 3.
MIC Series Power Supplies 3.3 MIC Non-IR Power Supply Units | en 23 Fuse Ratings CAUTION! Replace with only the same type and rating of the fuse for continued protection against the risk of fire, damage or injury. The power supply houses four (4) off 20 mm fuses in fuse holders. The ratings for these fuses are fixed on the low voltage secondary side but changes with the input voltage on the high voltage primary side.
en | MIC Non-IR Power Supply Units 3.4 MIC Series Power Supplies Installing a Non-IR Power Supply DANGER! ELECTRICAL SHOCK HAZARD Ensure the power is disconnected prior to opening the power supply enclosure. Power must be disconnected before replacing any fuse in the MIC PSU. The MIC power supplies have a separate internal shield covering the power cable input head-end (HD1).
MIC Series Power Supplies MIC Non-IR Power Supply Units | en 25 Figure 3.3 High voltage input head-end shield fitted inside the PSU enclosure 4. If using a conduit for the power cord, remove the blanking plug and install a suitable conduit in its place. Secure as recommended by the conduit manufacturer. 5. If using a power cord without a conduit, remove the blanking plug and fit the 1/2-in. NPT cable gland instead as depicted below.
en | MIC Non-IR Power Supply Units 6. MIC Series Power Supplies Carefully connect the Live and Neutral cores to the correct HD1 screw terminals as shown below and also printed on the PCB (next to the connector and not visible in the image above). 7. PCB Marking Terminal Identification Live HD1-L Neutral HD1-N Crimp a 6 mm ring terminal (supplied) to the earth core on the power cord using copper washers.
MIC Series Power Supplies Composite Cable Wire Color Red Green White Yellow Drain Wire Blue Violet Coax Core Coax Screen Black (optional) Orange (optional) MIC Non-IR Power Supply Units | en 27 Function MIC PSU PCB Marking AC supply AC supply return RX + Rx Ground Tx Tx + Video Video return Tamper switch Wash drive Terminal Block HD3-1 HD3-2 HD3-3 HD3-4 HD3-5 HD3-6 HD3-7 HD3-8 HD3-9 HD3-10 HD3-11 Power Power RxB RxA GND TxA TxB Video Vid 0V Tamp Sw Wash NOTICE! The earth core 6 mm ring crimp shoul
en | MIC Non-IR Power Supply Units MIC Series Power Supplies 10. Connect a tamper switch relay to HD2, if necessary. 11. Feed the coax cable through the cable gland and crimp the end with a BNC connector then connect the coax video cable to the CN1 head-end. Figure 3.7 Coaxial video connection 12. Use CN2 for additional add-on cards such as the 8-input alarm card or the Biphase card. 13.
MIC Series Power Supplies MIC Non-IR Power Supply Units | en 29 14. When wiring is complete, apply power and check the all four (4) LEDs are lit. – LED1 – 18 VAC power on to camera – LED2 – 18 VAC power on to camera – LED4 – Power on for optional heater – LED5 – Power on for optional heater 15. Re-attach the enclosure lid and screw it down until tight. 16. For installation of the MIC-WKT-KIT, MIC-ALM or MIC-BP-4 Biphase card please refer to the respective manuals. 3.
en | MIC Non-IR Power Supply Units 1. MIC Series Power Supplies Disconnect the power supply from the power source; locate the brown and gray wires in the shielded composite cable. 2. Using a terminal block (not supplied) connect the brown and gray wires from the speakers. 3. Feed the speaker cable through one of the conduit glands in the power supply unit enclosure. 4. Connect the speaker cable from a third party amplifier and microphone. 3.
MIC Series Power Supplies 3. 4. MIC Non-IR Power Supply Units | en 31 Break the two wire links and remove any excess solder. Solder the wire links using a soldering iron and TCW link wire from the left hand pads to the middle pads. Figure 3.10 5. Heater link set to +18 V The power supply will now deliver +18 VAC to head-end HD6. Composite Cable Function MIC PSU Terminal Block Wire Color Brown Heater1 or HD6-1 IR Lamps2 Gray Heater1 or HD6-2 IR Lamps2 1. See Section 3.
4 en | MIC IR Power Supply Units MIC Series Power Supplies MIC IR Power Supply Units Use this chapter to install the following MIC power supply units: – MIC-IR-240PSU-UL – MIC-IR-115PSU-UL – MIC-IR-24PSU-UL The power supplies for the MIC Series IR cameras are available in 230/115 VAC source and 24 VAC source versions. DANGER! ELECTRICAL SHOCK HAZARD Ensure the power is disconnected prior to opening the power supply enclosure. Power must be disconnected before replacing any fuse in the MIC PSU.
MIC Series Power Supplies MIC IR Power Supply Units | en 33 HD2 head-end provides the option for connection up to four (4) alarm inputs to the power supply. These can be tamper switches or inputs from other sensors or switches. Earth isolation and termination within the unit provides correct control of video earthing and thus prevents earth loops. WARNING! The washer pump relay is rated only to 24 VAC or VDC maximum voltage and is not suitable for Mains operated pumps. 4.
en | MIC IR Power Supply Units 4.2 MIC Series Power Supplies Fuse Ratings CAUTION! Replace with only the same type and rating of the fuse for continued protection against the risk of fire, damage or injury.
MIC Series Power Supplies 4.3 MIC IR Power Supply Units | en 35 MIC IR Power Supply Layout and Connections Figure 4.
en | MIC IR Power Supply Units 4.4 MIC Series Power Supplies Installing a MIC IR Power Supply DANGER! ELECTRICAL SHOCK HAZARD Ensure the power is disconnected prior to opening the power supply enclosure. Power must be disconnected before replacing any fuse in the MIC PSU. The MIC power supplies have a separate internal shield covering the power cable input head-end (HD1).
MIC Series Power Supplies MIC IR Power Supply Units | en 37 Figure 4.3 High voltage input head-end shield fitted inside the PSU enclosure 4. If using a conduit for the power cord, remove the blanking plug and install a suitable conduit in its place, secure as recommended by the conduit manufacturer. 5. If using a power cord without a conduit, remove the blanking plug and fit the 1/2-in. NPT cable gland instead.
en | MIC IR Power Supply Units Figure 4.4 1 2 3 4 8. MIC Series Power Supplies Mains cable wired into HD1 showing earth terminal connections Enclosure lid earth cable Earth core from power supply PCB Earth core from Mains cable Enclosure earth termination post Feed the remaining video and telemetry cables through the appropriate sized glands. 9.
MIC Series Power Supplies MIC IR Power Supply Units | en 39 NOTICE! The earth core 6 mm ring crimp should be a Tyco Electronics, 00321045-0, PIDG, M6, BLUE, UL certification CCN ZMVV, file E13288. A suitable ring crimp tool for fitting the ring crimp is a Davico type DHCR15 or equivalents. 10. Connect the brown and gray wires for the IR lamps to HD6. Composite Cable Function Wire Color Brown Gray IR Lamp + IR Lamp - Terminal PCB head-end HD6-1 HD6-2 Marking IR+ IR- 11.
en | MIC IR Power Supply Units MIC Series Power Supplies 13. Crimp or screw telemetry connections to head-ends HD4 and HD5 to connect the MIC camera to the control room as shown below. Telemetry Signal Name RxB or Rx RxA or Rx + GND TxA or Tx TxB or Tx + HD3 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 HD4 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 HD5 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 14. A washer drive is provided as standard on the IR power supplies. A 24 VAC rated relay is fitted via the on board fuse F S4 (rated at 2 Amps).
MIC Series Power Supplies MIC IR Power Supply Units | en 41 Figure 4.6 MIC Series IR power supply LED positions 1 LED 1 and Indicates that 18 VAC is available from the LED 2 power supply and that the supply fuses are intact. There is no indication of the operation of the telemetry lines as this would increase the load on these lines reducing the number of cameras that can be driven by a single telemetry spur. 2 LED 3 Illuminates when the washer drive relay is on.
en | MIC IR Power Supply Units 4.5 MIC Series Power Supplies Commissioning the IR Lamps The following instructions apply to all MIC IR cameras. Connect a camera to a PC via RS422/485 telemetry and to the MIC Series Universal Camera Setup Software (see the MIC Series Universal Camera Setup Software Manual for further details), before applying power to the power supply, check that all connections are correct.
MIC Series Power Supplies 5 Technical Specifications | en 43 Technical Specifications The MIC power supplies are fitted into a cast aluminium IP65 rated enclosure with the following specifications: MIC PSU Voltage Hz Power Output MIC-240PSU-UL 230 VAC 50/60 Hz 40 VA 18 VAC MIC-115PSU-UL 115 VAC 50/60 Hz 40 VA 18 VAC MIC-24PSU-UL 24 VAC 50/60 Hz 40 VA 18 VAC MIC-IR-240PSU-UL 230 VAC 50/60 Hz 60 VA 18 VAC MIC-IR-115PSU-UL 115 VAC 50/60 Hz 60 VA 18 VAC MIC-IR-24PSU-UL 24 VAC
en | Technical Specifications 5.1 MIC Series Power Supplies Dimensional Drawings 90.5 mm (3.6 in.) 288 mm (11.3 in.) 260 mm (10.2 in.) 110 mm (4.3 in.) 160 mm (6.3 in.) 240 mm (9.5 in.) F.01U.141.598 | 1.0 | 2009.11 Installation Manual Bosch Security Systems, Inc.
Bosch Security Systems, Inc. . www.boschsecurity.com © Bosch Security Systems, Inc.