User Manual

MIC Series IP Power Supply Configuration using a Web browser | en 55
Bosch Security Systems, Inc. User Manual F.01U.265.804 | 1.6 | 2012.08
Alarm Output
Select N.O. if the alarm is to be triggered when the contact closes. Select N.C. if the alarm is
to be triggered when the contact opens.
4.28.3 Alarm Rules
The encoder features an alarm rule engine. In its simplest form, an alarm rule can define
which input(s) activate which output(s). An alarm rule allows you to customize the encoder to
respond automatically to different alarm inputs.
To configure an alarm rule, specify one input from either a physical connection, a motion
detection trigger, or from a connection to the camera’s Livepage. The physical input
connection can be activated by dry contact devices such as pressure pads, door contacts and
similar devices. Next, specify up to two (2) rule outputs, or the camera’s response to the
input. Outputs include a physical alarm relay, an AUX command, or a preposition scene.
1. Click the Enabled check box to activate the alarm.
2. Enter the Name of the alarm rule.
3. Choose one of the following alarm inputs:
Alarm Input 1: a physical alarm connection.
Alarm Input 2: a physical alarm connection.
IVA/MOTION+: an alarm when IVA or motion detection is activated.
Connection: an alarm when an attempt is made to access the camera’s IP address.