62 en | Configuration using a Web browser MIC Series IP Power Supply
F.01U.265.804 | 1.6 | 2012.08 User Manual Bosch Security Systems, Inc.
Export to FTP
Select this parameter if you want all alarm recordings to be exported to an FTP server
automatically. Make sure to have inserted all relevant data for FTP posting (see
Section 4.46 FTP Posting, page 79).
Alarm input / Analysis alarm / Video loss alarm
Here you can select the alarm sensor that is to trigger a recording.
Virtual alarm
Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+
commands or alarm scripts, for example.
4.34 Retention Time
You can specify the retention times for recordings. If the available memory capacity of a
medium has been used, older recordings are only overwritten if the retention time entered
here has expired.
Recording 1 / Recording 2
Enter the required retention time in hours or days for each recording.
NOTICE!
The alarm inputs are configured and activated on the Alarm Inputs page (see
Section 4.28.1 Input Options, page 54).
The numbering of the checkboxes for the alarm inputs corresponds to the labeling of the
alarm inputs on the encoder.
NOTICE!
For more information, please see the Alarm Task Script Language document and the RCP+
documentation. These documents can be found on the product CD supplied.
NOTICE!
Make sure that the retention time corresponds with the available memory capacity. A rule of
thumb for the memory requirement is as follows: 1 GB per hour retention time with 4CIF for