No parity check
–1 stop bit
No protocol
Command inputs
After the connection has been established, you must log on to the encoder to access the main
menu. Other submenus and functions can be accessed using the on-screen commands.
1. If necessary, turn off the local echo so that entered values are not repeated on the
display.
2. Enter one command at a time.
3. When you have entered a value, such as the IP address, check the characters you have
entered before pressing Enter to transfer the values to the encoder.
Assigning an IP address
Before you can operate the encoder in your network you must first assign it an IP address that
is valid for your network.
The following default address is preset at the factory: 192.168.0.1
1. Start a terminal program such as HyperTerminal.
2. Enter the user name service. The terminal program displays the main menu.
3. Enter command 1 to open the IP menu.
4. Enter 1 again. The terminal program displays the current IP address and prompts you to
enter a new IP address.
5. Enter the desired IP address and press Enter. The terminal program displays the new IP
address.
6. Use the displayed commands for any additional settings you require.
Reboot
Briefly interrupt the power supply to the encoder for a reboot (disconnect the power supply
unit from the mains supply and switch on again after a few seconds).
Additional parameters
You can use the terminal program to check other basic parameters and modify them where
necessary. Use the on-screen commands in the various submenus to do this.
NOTICE!
You must reboot to activate the new IP address, a new subnet mask or a gateway IP address.