4. Set the user password of all the remote stations to be
accessed using this password.
Setting destination 10 to the IP-address 0.0.0.0 overrides its
function as the tenth address to try.
Video transmission
If the unit is operated behind a firewall, select TCP (HTTP port)
as the transfer protocol. For use in a local network, select UDP.
To enable multicast operation, select UDP for the Video
transmission parameter here and on the Network Access page.
Note:
In the event of an alarm, a larger network bandwidth is
sometimes required for additional video streams (if multicast
operation is not possible).
Stream
Select a stream to be transmitted.
Remote port
Select an appropriate browser port depending on the network
configuration.
The ports for HTTPS connections are only available if SSL
encryption is set to On.
Video output
If a hardware receiver is used, select the analog video output to
which the signal should be switched. If the destination device is
unknown, select First available. This places the image on the
first video output with no signal.
The connected monitor only displays images when an alarm is
triggered.
Note:
Refer to the destination unit documentation for more
information on image display options and available video
outputs.