Surveillance Cabinet NDA-U-PA0 | NDA-U-PA1 | NDA-U-PA2 en Installation manual
Surveillance Cabinet Table of Contents | en 3 Table of contents 1 Important Safety Instructions 4 1.1 Safety precautions 4 1.2 Important safety instructions 4 1.3 Important Notices 5 1.4 UL certification 6 1.5 Bosch notices 7 2 Unpacking 8 2.1 Parts list 8 2.2 Optional mounting accessories 8 2.3 Description 8 2.4 Tools required 3 Installing the Surveillance cabinet 3.1 Pre-installation checklist 10 3.2 Mounting the Surveillance cabinet 11 3.
en | Important Safety Instructions 1 Surveillance Cabinet Important Safety Instructions Read, follow, and retain all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operation. 1.1 Safety precautions Danger! High risk: This symbol indicates an imminently hazardous situation such as “Dangerous Voltage” inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death.
Surveillance Cabinet Important Safety Instructions | en 6. 5 Power sources - Operate the unit only from the type of power source indicated on the label. Before proceeding, be sure to disconnect the power from the cable to be installed into the unit. – For battery powered units, refer to the operating instructions. – For external power supplied units, use only the recommended or approved power supplies. – For limited power source units, this power source must comply with EN60950.
en | Important Safety Instructions Surveillance Cabinet Disposal - Your Bosch product was developed and manufactured with highquality material and components that can be recycled and reused. This symbol means that electronic and electrical appliances, which have reached the end of their working life, must be collected and disposed of separately from household waste material. Separate collecting systems are usually in place for disused electronic and electrical products.
Surveillance Cabinet Important Safety Instructions | en 7 Disclaimer Underwriter Laboratories Inc. (“UL”) has not tested the performance or reliability of the security or signaling aspects of this product. UL has only tested fire, shock and/or casualty hazards as outlined in UL's Standard(s) for Safety for Information Technology Equipment, UL 60950-1. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product.
en | Unpacking 2 Surveillance Cabinet Unpacking – This equipment should be unpacked and handled with care. Check the exterior of the packaging for visible damage. If an item appears to have been damaged in shipment, notify the shipper immediately. – Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. – Do not use this product if any component appears to be damaged.
Surveillance Cabinet Unpacking | en – 9 3/4 in. (20-mm) NPS right angle conduit connector - if installing a mast (pole) mount with a VG4-ARM-WPLATE Bosch Security Systems Installation manual 2017.09 | v1.0 | F.01U.250.
en | Installing the Surveillance cabinet Surveillance Cabinet 3 Installing the Surveillance cabinet 3.1 Pre-installation checklist 1. Make sure that you have the correct camera and accessories for the installation in your environment. 2. Determine the location and distance for the unit based on its voltage and current consumption. Prepare the wires and connections that are necessary to connect your camera. 3.
Surveillance Cabinet 3.2 Installing the Surveillance cabinet | en 11 Mounting the Surveillance cabinet Before you mount the unit, decide if you route the wires through the holes in the bottom or in the back of the unit. If you choose the holes in the back, move the 2 seal plugs to the holes in the bottom before you mount the unit. Use 20 mm (3/4 inch) NPS fittings for the holes on the bottom and back of the unit. Use 15 mm (1/2-inch) NPS fittings for the side holes. 1.
en | Installing the Surveillance cabinet Surveillance Cabinet XF103 DOME HTR 54321 P107 XF101 (FUSE) J103 (LED) LINE NC NEUT 123 P106 GND TXD RXD XF102 P101 (FUSE) J101 J102 (FUSE) TRANSFORMER (115/230VAC MODELS) P105 C+ C- 6 5 4 3 2 1 GND TXD RXD C+ C- 6 5 4 3 2 1 Overview of connections in the unit 1 Ground Screw 7 P101 Connector; Power in (120 VAC / 220 VAC) 2 Not used 8 P106 Connector; not used 3 In/Out; 15 mm (1/2 inch) NPS 9 P105 Connector; not used Fitting
Surveillance Cabinet ! Installing the Surveillance cabinet | en 13 Warning! Fuse replacement by qualified service personnel only. Replace with same type fuse. Fuse Specifications No. P101 Volts XF101 Mains XF102 Camera XF103 Heater 24 V T 5.0 A T 2.0 A T 3.15 A 115 V T 1.6 A T 2.0 A T 3.15 A 230 V T 0.8A T 2.0 A T 3.
3.4 en | Installing the Surveillance cabinet Surveillance Cabinet Routing power through intermediate unit You can route the main power supply through an intermediate unit (type PA1 or PA2) before connecting the power to a PA0 type unit. This chapter describes how to make the connections for this configuration. You must change the connectors, because the 5-pin power out connector from the PA1 or PA2 unit does not match to the 3-pin power input of the PA0 power supply.
Surveillance Cabinet Installing the Surveillance cabinet | en 15 For the correct connection of the incoming high voltage and the outgoing low voltage wires, refer to this table: No. Connector Pin 1 Pin 2 Ground Grounding screw P101 120/230 VAC power in Line P107 24 VAC power out NC Pin 3 Pin 4 Pin 5 Heater Heater (24 VAC) (24 VAC) Pin 6 Neutral Ground Table 3.2: NDA-U-PA1 / NDA-U PA2 Surveillance cabinet connections 1.
en | Installing the Surveillance cabinet Surveillance Cabinet Warning! ! Make sure that you connect the outgoing power supply wires to the P107 heater connectors (HN and HL). The heater power fuse (XF103) can handle a higher amperage (3.15 A) than the camera power (XF102) fuse (2.0 A). 6. Route the 24 VAC outgoing power supply wires into the PA0 unit through the conduit fitting on the left side of the unit. 7.
Surveillance Cabinet Installing the Surveillance cabinet | en 17 See also – Bosch Security Systems Attaching the door, page 18 Installation manual 2017.09 | v1.0 | F.01U.250.
en | Installing the Surveillance cabinet Surveillance Cabinet Attaching the door 3.5 The bottom hinge pin of the door has a Hinge Pin Stop to hold the hinge open when you attach the arm to the unit. 1. Push the bottom hinge pin down and rotate it behind the Hinge Pin Stop. 2. Push the top hinge pin up and hold it. Notice! Both Hinge Pins must be fully pushed to unlock the hinges of the door and before you proceed to the next step. 3.
Surveillance Cabinet 3.6 Installing the Surveillance cabinet | en 19 Attaching the Pendant pipe mount or Pendant wall mount To attach accessories such as a Pendant pipe mount or Pendant wall mount, refer to the documentation that comes with your accessory. Notice! The accessory comes with a watertight plug. When you attach the accessory to the door, always use the plug to make a watertight cable feed through. 3.
en | Connections for video, control, alarm and relay Surveillance Cabinet 4 Connections for video, control, alarm and relay 4.1 Using fiber optic ethernet media converter to transmit video and control The Small Form-factor Pluggable (SFP) modules are available as multi-mode fiber (MMF) or single-mode fiber (SMF) models with a single SC connector or dual-fiber with an LC connector. Refer to the VG4-SFPSCKT Fiber Optic Media Converter Installation Guide.
Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V.