FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR NDV‑3502‑F02 | NDV‑3502‑F03 | NDV‑3503‑F02 | NDV‑3503‑F03 | NTV‑3502‑F02L | NTV‑3502‑F03L | NTV‑3503‑F02L | NTV‑3503‑F03L | NDE‑3502‑AL | NDE‑3503‑AL | NBE‑3502‑AL | NBE‑3503‑AL en User manual
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Table of contents | en 3 Table of contents 1 Browser connection 5 1.1 System requirements 5 1.2 Establishing connection 5 1.3 Password Network 6 2 System overview 7 2.1 Live page 7 2.2 Playback 7 2.3 Configuration 7 2.4 Dashboard 8 3 Operation via the browser 9 3.1 Live page 9 3.2 Playback page 11 3.2.1 Selecting the recording stream 11 3.2.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Table of contents 4.4.8 SD Card Status 37 4.5 Alarm 37 4.5.1 Alarm Connections 37 4.5.2 Video Content Analysis (VCA) 39 4.5.3 Audio Alarm 43 4.5.4 Alarm E-Mail 43 4.5.5 Alarm Task Editor 44 4.6 Interfaces 44 4.6.1 Alarm Inputs 44 4.6.2 Alarm Outputs 45 4.7 Network 45 4.7.1 Network Services 45 4.7.2 Network Access 45 4.7.3 DynDNS 47 4.7.4 Advanced 48 4.7.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 1 Browser connection | en 5 Browser connection A computer with Microsoft Internet Explorer is used to receive live images, control the unit, and replay stored sequences. The unit is configured over the network using the browser. 1.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Browser connection 1.3 Password Network If a RADIUS server is used for network access control (802.1x authentication), the unit must be configured first. To configure the unit, connect it directly to a computer using a network cable and configure the two parameters, Identity and Password. Only after these have been configured can communication with the unit via the network occur.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 2 System overview | en 7 System overview When a connection is established, the Live page is initially displayed. The application bar displays the following icons: Live Click this icon to view the live video stream. Playback Click this icon to play back recorded sequences. This link is only visible if a storage medium has been configured for recording. (With VRM recording, this option is not active.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | System overview 2.4 Dashboard The Dashboard page is used to display detailed information about the device. The Dashboard is only visible in the application bar if the Show 'Dashboard' option is enabled by a service-level user in the Configuration -> Web Interface -> Appearance page. 2020-01 | V02 | DOC User manual Bosch Security Systems B.V.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Operation via the browser | en 3 Operation via the browser 3.1 Live page 9 After the connection is established, the Live page is initially displayed. It shows the live video image on the right of the browser window. Depending on the configuration, various text overlays may be visible on the live video image. Other information may also be shown next to the live video image.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Operation via the browser Recording status The hard drive icon below the live camera image changes during an automatic recording. The icon lights up and displays a moving graphic to indicate a running recording. If no recording is taking place, a static icon is displayed.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Operation via the browser | en 11 Status icons Various overlays in the video image provide important status information. The overlays provide the following information: Decoding error The frame might show artifacts due to decoding errors. Alarm flag Indicates that an alarm has occurred.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Operation via the browser 1. To limit the search to a particular time range, enter the date and times for the start and stop points. 3.2.3 2. Select an option from the drop-down box to define a search parameter. 3. Click Search. 4. The results are shown. 5. Click a result to play it back. 6. Click Back to define a new search.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 3. Bosch Security Systems B.V.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 4 Configuration 4.1 General 4.1.1 Identification Device name Assign a unique name to assist in identification. This name simplifies the management of multiple devices in more extensive systems. The name is used for remote identification, for example, in the event of an alarm. Choose a name that makes it as easy as possible to identify the location unambiguously.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR – Configuration | en 15 Active Directory server (AD FS). A check mark in this check box indicates that the device uses an active directory server. Creating a new user To create a new user, click Add in the section below Authentication modes. In the box User, fill in the fields: 1. User name: Enter a name with a minimum of 5 and a maximum of 31 characters. 2.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration First, check the time zone setting. If it is not correct, select the appropriate time zone and click Set. 1. Click Details to edit the DST table. 2. Click Generate to fill the table with the preset values from the unit. 3. Click one of the entries in the table to make changes. The entry is highlighted. 4. Click Delete to remove the entry from the table. 5.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR – Configuration | en 17 Logo only: The logo will be shown without the Camera name stamping. Time stamping Select the position of the time and date overlay in the drop-down box. It can be displayed at the Top, at the Bottom, or at a position of choice using the Custom option, or it can be set to Off for no overlay information. If the Custom option is selected, enter values in the X and Y position fields.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 4.1.5 GB/T 28181 This page allows you to set the parameters for conformance to the GB/T 28181 national standard “Security and protection video monitoring network system for information transport, switch and control”. This standard is specifically for China.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 19 Device logo To replace the device name in the top-left part of the window, enter the path to a suitable image in this field. The image file must be stored on a web server. Show VCA metadata When video content analysis (VCA) is activated, additional information is displayed in the live video stream.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration JPEG resolution You can specify the size of the JPEG image on the Live page. Options are Small, Medium, Large, 720p, 1080p, and “Best possible” (default). JPEG interval You can specify the interval at which the individual images should be generated for the MJPEG image on the Live page. JPEG quality You can specify the quality at which the JPEG images appear on the Live page.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 21 Path for JPEG and video files Enter the path for the storage location of individual images and video sequences saved from the Live page. Video file format Select a file format for the live page display. The MP4 format does not include metadata. Click Set to apply the changes. 4.3 Camera 4.3.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 4. If the IR-corrected lens box is unchecked, select the other Day/night mode and readjust the focus for this mode. Reboot device Click Reboot to restart the device. Factory defaults Click Defaults to restore the factory defaults for the camera. A confirmation screen appears. Allow several seconds for the camera to optimize the picture after a reset.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 23 The focal length is determined by the lens. The shorter the focal length, the wider the field of view. The longer the focal length, the narrower the field of view and the higher the magnification. Show sensor values... Click to automatically see the camera parameters, for example, Tilt angle [°], Roll angle [°] and Focal length [mm].
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration – Remove a line or angle. To do this, select the line or angle, then click the trash can icon. Note: Blue lines indicate calibration elements added by you. White lines represent the element as it should be positioned on the camera image based on the current calibration results or the determined calibration data.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 4.3.2 Configuration | en 25 Color Brightness (0...255) Adjust the brightness with the slider from 0 to 255. Contrast (0...255) Adjust the contrast with the slider from 0 to 255. Saturation (0...255) Adjust the color saturation with the slider from 0 to 255. White balance – Basic auto mode allows the camera to continually adjust for optimal color reproduction using an average reflectance method.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration ALC level Adjust the video output level (-15 to 0 to +15). Select the range within which the ALC will operate. A positive value is more useful for lowlight conditions; a negative value is more useful for very bright conditions. Exposure Automatic exposure Select to let the camera automatically set the optimum shutter speed.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 4.3.4 Configuration | en 27 Enhance High dynamic range Choose between these options: Off: to disable High Dynamic Range (HDR) Auto: for automatic HDR. Depending on the scene, the camera can capture multiple exposures to increase the Dynamic Range Extreme: similar to Auto, but with even higher Dynamic Range. Use this only in quiet scenes and with low light levels.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 4.3.5 Encoder Profile Profiles are rather complex and include a number of parameters that interact with one another, so it is generally best to use the pre-defined profiles. Only change a profile if completely familiar with all the configuration options. Changing a profile To change a profile, select it by clicking its tab and then change the parameters within that profile.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 29 Allow enhanced prediction This function allows for multiple references in H.264 and H.265 streams, which can reduce bitrate. Some decoders do not support this feature and therefore can be disabled. Min. P-frame QP In the H.264-protocol, the Quantization Parameter (QP) specifies the degree of compression and thus the image quality for every frame.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Profile 2 For a high resolution image, the video bit rate and frame quality are adjusted to a median profile for everyday use.. Profile 3 For a high resolution image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 4.3.9 Configuration | en 5. If required, select another region and repeat the steps. 6. To remove a region, select the area and click the waste bin icon. 7. Click Set to apply the region settings. 31 Privacy Masks Privacy masking is used to block a specific area of a scene from being viewed. Eight privacy mask areas can be defined. 1. Select the pattern color for the masks. 2.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 1. Click and hold the Send audio button to send an audio signal to the unit. 2. Release the button to stop sending audio. You must have a speaker or similar connected to the line out of the camera in order to send the audio. Click Set to apply the changes. 4.3.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR – Configuration | en 33 The connection to the IP address is established. The Storage overview field displays the logical drives. Local Media An SD card inserted in the camera can be used for local recording. 4 If the SD card is password protected, enter the password into the Password field. The Storage overview field displays the local media.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 4.4.2 Recording Profiles A recording profile contains the characteristics of the tracks that are used for recording. These characteristics can be defined for ten different profiles. The profiles can then be assigned to days or times of day on the Recording Scheduler page. Each profile is color-coded. The names of the profiles can be changed on the Recording Scheduler page.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 35 Alarm triggers Select the alarm type that is to trigger a recording: – Alarm input – Analysis alarm – Virtual alarm: select one of the sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example. Export to account Select an account from the drop-down box to export to an account.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Recording status The graphic indicates the recording activity. An animated graphic is displayed when recording is taking place. Activating recording After completing configuration, activate the recording schedule and start scheduled recording. Once activated, the Recording Profiles and the Recording Scheduler are deactivated and the configuration cannot be modified.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 37 Posting interval Enter the interval in seconds at which the images are sent to an FTP server. Enter zero for no images to be sent. Target Select the target account for JPEG posting. Notice! You must configure an account in order to have functionality for Image Posting. Click on Configure accounts to do so. Click Set to apply the changes. 4.4.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration 3. Enter the password in the Destination password field. 4. Set the user password of all the remote stations to be accessed using this password. Setting destination 10 to the IP-address 0.0.0.0 overrides its function as the tenth address to try. Video transmission If the unit is operated behind a firewall, select TCP (HTTP port) as the transfer protocol.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 4.5.2 Configuration | en 39 Video Content Analysis (VCA) The camera has integrated Video Content Analysis (VCA) which detects and analyzes changes in the picture using image processing algorithms. Such changes can be due to movements in the camera's field of view. Detection of movement can be used to trigger an alarm and to transmit metadata.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Scenario Scenarios are applications with pre-defined settings that are adapted to specific use cases. All relevant settings, from tasks to metadata, are set automatically by the system.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 3. Configuration | en 41 Check the box Reference check to activate the on-going check. The stored reference image is displayed in black and white below the current video image. 4. Select the Disappearing edges or Appearing edges option to specify the reference check once again.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Scheduled A scheduled configuration allows you to link a VCA profile with the days and times at which the video content analysis is to be active. 4 In the VCA configuration drop-down list, select Scheduled. Schedules can be defined for weekdays and for holidays. Assign as many time periods (in 15-minute intervals) as needed for any day of the week.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 4.5.3 Configuration | en 43 Audio Alarm Alarms can be generated based on audio signals. Configure signal strengths and frequency ranges so that false alarms, for example, machine noise or background noise, are avoided. Set up normal audio transmission before configuring the audio alarm. Audio alarm Select On for the device to generate audio alarms.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Attach JPEG from camera To send a JPEG image from a particular video channel, check the appropriate box. VCA overlays Select the VCA overlays check box, to place the outline of the object that triggered an alarm into the camera image sent as snapshot via e-mail. Destination address Enter the e‑mail address for alarm e‑mails here. The maximum address length is 49 characters.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 45 Action Select a type of action to be performed when an alarm input occurs: – None – Monochrome This switches the camera to the monochrome mode. Click Set to apply the changes. 4.6.2 Alarm Outputs Configure the switching behavior of the output. Select different events that automatically activate an output.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration For certain applications, the DHCP server must support the fixed assignment between IP address and MAC address, and must be appropriately set up so that, once an IP address is assigned, it is retained each time the system is rebooted. Ethernet The Ethernet options are defined in this section. IP V4 address IP address Enter the desired IP address for the camera.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 47 To limit connections to SSL encryption, set the Off option in the HTTP browser port and the RCP+ port. This deactivates all unencrypted connections allowing connections on the HTTPS port only. Configure and activate encryption for media data (video, audio, metadata) on the Encryption page. Minimum TLS version Select the version for minimum Transport Layer Security (TLS).
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration User name Enter the user name you registered. Password Enter the password you registered. Force registration now Force the registration by transferring the IP address to the DynDNS server. Entries that change frequently are not provided in the Domain Name System. It is a good idea to force the registration when setting up the device for the first time.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 49 TCP metadata input The device can receive data from an external TCP sender, for example an ATM or POS device, and store it as metadata. Select the port for TCP communication. Select Off to deactivate the function. Enter a valid Sender IP address. Syslog Server IP address Enter the appropriate IP address of the server. Server port (0 = Off) Enter the number of the server port.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Note: To use the UPnP function on a Windows computer, both the Universal Plug-and-Play Device Host and the SSDP Discovery Service must be activated. Quality of service The priority of the different data channels can be set by defining the DiffServ Code Point (DSCP). Enter a number between 0 and 252 as a multiple of four.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 51 Metadata You can enable multicast metadata here. The configuration follows the same pattern as for video multicast, but without the streaming option. Define a multicast address and define a port. Audio You can enable multicast audio for different encoders here. The configuration follows the same pattern as for video multicast, but without the streaming option.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration If either of these ranges are set, no IP V6 addresses are allowed to actively connect to the device. The device itself may initiate a connection (for example, to send an alarm) outside the defined ranges if it is configured to do so. 4.8 Service 4.8.1 Maintenance Notice! Before starting a firmware update, make sure to select the correct upload file.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Configuration | en 53 The progress bar allows monitoring of the transfer. The time remaining is shown by the message going to reset Reconnecting in ... seconds. When the upload is completed successfully, the device reboots automatically. To save the camera settings: 1. Click Download. A dialog box appears. 2. Enter a password to protect the configuration file. 3.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Configuration Download a certificate Click on the download icon and a window opens with base64 encoded text of the certificate. Click Set to apply the changes. 4.8.4 Logging Event Logging Current log level Select the level of event for which to display log entries or to log. Number of displayed entries Select the number of entries to display.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR 5 Troubleshooting 5.1 Physical reset button Troubleshooting | en 55 Each camera has a hardware reset button. You may need to press the reset button to reset the camera to factory defaults if you encounter the following circumstances: – You can power up the camera but cannot log on to the camera using the web browser. – The camera doesn’t start up, or fails to power up via PoE.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR en | Appendices 6 Appendices 6.1 Copyright notices The firmware uses the fonts "Adobe-Helvetica-Bold-R-Normal--24-240-75-75-P-138-ISO10646-1" and "Adobe-Helvetica-Bold-R-Normal--12-120-75-75-P-70-ISO10646-1" under the following copyright: Copyright 1984-1989, 1994 Adobe Systems Incorporated. Copyright 1988, 1994 Digital Equipment Corporation.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR Bosch Security Systems B.V.
FLEXIDOME IP 3000i IR | FLEXIDOME IP micro 3000i | DINION IP 3000i IR | FLEXIDOME IP turret 3000i IR | Appendices 2020-01 | V02 | DOC User manual Bosch Security Systems B.V.
Bosch Security Systems B.V. Torenallee 49 5617 BA Eindhoven Netherlands www.boschsecurity.com © Bosch Security Systems B.V.