Installation Instructions

7
Electrical Installation
Electrical requirements
You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junctionbox must be located within 3 feet of the cooktop
connection. It should be easily accessible for service
purposes.
Refer to data plate for more information. See “Data Plate”
under “Service” for data plate location.
Power supply
Connect Electrical Supply
9 WARNING
Before installing, turn off at the service panel. Lock
service panel to prevent power from being turned
on accidentally.
The electrical power supply system should be a 1-phase,
3-wire system with ground connection. Install suitable
junction box (not furnished). An appropriately-sized, UL-
listed conduit connector must be used to correctly attach
the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical Code
and all local codes and ordinances.
Attach flexible conduit to the junction box.
Metal conduit and leads are factory installed.
9 WARNING
To reduce the risk of electrical shock and fire, do
not use a flexible power-supply cord with this
appliance. Connect only to a 3 wire, 120/240-volt
power supply; the neutral conductor is not required
for the operation of the appliance. The potential at
the power supply electrical connections shall be
150-volts-to-ground or less.
Connect the cooktop lead wires to the junction box
supply wires in proper phase:
black (L1) to black
red (L2) to red
green or blank copper wire to ground
Check the Installation
9 WARNING
Before you turn on power supply, make sure all
controls are in the OFF position.
Remove everything from the cooktop surface including
stickers. Clean cooktop surface with cooktop cleaning
creme.
Switch on the circuit breaker.
Verify that elements function properly.
Model 240 V AC, 60 Hz
system: circuit
breaker
208 V AC, 60 Hz
system: circuit
breaker
NET8068SUC 40 Amp 30 Amp
NET8068UC 40 Amp 30 Amp
NET8668SUC 50 Amp 40 Amp
NET8668UC 50 Amp 40 Amp
NETP068SUC 40 Amp 40 Amp
NETP668SUC 40 Amp 40 Amp
NEM5066UC 30 Amp 30 Amp
NEM5666UC 40 Amp 40 Amp
PP
PP
-ER[
&RQGXLWDSSUR[
IHHWaPP

PP
)LWWLQJ&RQGXLW
PP
DSSUR[