Installation instructions
Table Of Contents
- Built-in gas hob
- en-us
- Table of contents
- 1 IMPORTANT SAFETY INSTRUCTIONS
- 1.1 Safety definitions
- 1.2 General information
- 1.3 General safety instructions
- 1.4 Appliance handling safety
- 1.5 Safety codes and standards
- 1.6 Electrical safety
- 1.7 Gas safety
- 1.8 Propane gas installation
- 1.9 Ventilation recommendations
- 1.10 High altitude installation
- 1.11 State of California Proposition 65 Warnings
- 2 Before you begin
- 3 Prepare installation space
- 4 Installation procedure
- 4.1 Preparing the cooktop
- 4.2 Installing the pressure regulator
- 4.3 Securing the cooktop to the countertop
- 4.4 Connection overview
- 4.5 Connecting the gas supply line
- 4.6 Connecting the electrical supply
- 4.7 Assembling the burner parts
- 4.8 OptiSim® feature
- 4.9 Installing the burner grates
- 4.10 Checking the installation
- 5 Conversion to LP gas
- 6 Customer Service
- fr-ca
- Table des matières
- 1 IMPORTANTES CONSIGNES DE SÉCURITÉ
- 1.1 Définitions des termes de sécurité
- 1.2 Indications générales
- 1.3 Consignes générales de sécurité
- 1.4 Manipulation sécuritaire des appareils
- 1.5 Codes et normes de sécurité
- 1.6 Sécurité électrique
- 1.7 Sécurité des gaz
- 1.8 Installation au gaz propane
- 1.9 Recommandations de ventilation
- 1.10 Installation à haute altitude
- 1.11 Mises en garde conformément à la proposition 65 de l'État de Californie
- 2 Avant de commencer
- 3 Préparation préalable au montage
- 4 Procédure d’installation
- 4.1 Préparation de la table de cuisson
- 4.2 Installation du régulateur de pression
- 4.3 Fixation de la table de cuisson au comptoir
- 4.4 Aperçu de la connexion
- 4.5 Raccordement de la conduite d’alimentation en gaz
- 4.6 Connexion de l'alimentation électrique
- 4.7 Assemblage des pièces du brûleur
- 4.8 OptiSim® fonctionnalité
- 4.9 Installation des grilles de brûleur
- 4.10 Inspecter l’installation
- 5 Conversion au gaz LP
- 6 Service à la clientèle
- es-mx
- Tabla de contenidos
- 1 INSTRUCCIONES DE SEGURIDAD IMPORTANTES
- 1.1 Definiciones de seguridad
- 1.2 Indicaciones generales
- 1.3 Instrucciones generales de seguridad
- 1.4 Seguridad de manejo del aparato
- 1.5 Códigos y normas de seguridad
- 1.6 Seguridad eléctrica
- 1.7 Seguridad de los aparatos de gas
- 1.8 Instalación con gas propano
- 1.9 Recomendaciones de ventilación
- 1.10 Instalación a gran altitud
- 1.11 Advertencias en virtud de la Proposición 65 del estado de California
- 2 Antes de empezar
- 3 Preparar el lugar de instalación
- 4 Procedimiento de instalación
- 4.1 Preparación de la placa de cocción
- 4.2 Instalar el regulador de presión
- 4.3 Asegurar la parrilla a la superficie de trabajo
- 4.4 Descripción general de la conexión
- 4.5 Conectar el conducto de suministro de gas
- 4.6 Conectar el suministro eléctrico
- 4.7 Colocar los componentes de los quemadores
- 4.8 Función OptiSim®
- 4.9 Instalar las rejillas de los quemadores
- 4.10 Comprobar la instalación
- 5 Conversión a gas LP
- 6 Servicio de atención al cliente
en-us
6
1.8 Propane gas installation
¡ The propane gas tank must be equipped with its own
high pressure regulator. In addition, the regulator sup-
plied with this unit must also be used.
¡ The appliance is shipped from the factory for use with
natural gas. It must be converted for use with propane.
A qualified technician or certified installer must do the
conversion.
¡ For use with propane the appliance must be converted
per the LP conversion instructions.
→
"Conversion to LP gas", Page13
For Massachusetts installations
¡ Installation must be performed by a qualified or li-
censed contractor, plumber or gas fitter qualified or li-
censed by the state, province or region where this ap-
pliance is being installed.
¡ Shut-off valve must be a “T” handle gas cock.
¡ Flexible gas connector must not be longer than
36inches.
Installer - show the owner where the gas shut-off valve is
located.
1.9 Ventilation recommendations
We strongly recommend the installation of a ventilation
hood above this appliance.
The hood must be installed according to instructions fur-
nished with the hood.
WARNING
The appliance should not be installed with a ventilation
system that blows air downward toward the burners. This
type of ventilation system may cause ignition and combus-
tion problems with the gas cooking appliance resulting in
personal injury or unintended operation.
1.10 High altitude installation
This appliance has been tested for operation up to an alti-
tude of 10,100ft (3,080m) elevation above sea level.
For altitudes above 2,000ft (610m) elevation above sea
level, burner flame adjustments may be necessary.
Burners should be checked at the lowest setting, if the
flame is not stable the simmer should be increased until
the flame is stable. This can be done by adjusting the by-
pass screw in the valve. If flame performance is satisfac-
tory, adjustment will not be required. It is required that a
certified professional make the high altitude adjustments
during installation.
1.11 State of California Proposition 65
Warnings
This product may contain a chemical known to the State
of California, which can cause cancer or reproductive
harm. Therefore, the packaging of your product may bear
the following label as required by California:
IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS