Before You Begin
Parts Included
Installation kit contents
Main orifices
Tools and Parts Needed
Component Quantity
Conversion Kit Instructions 1
Conversion sticker 1
Foam tape 1
112 orifice 1
106 orifice 1
88 orifice 3
65 orifice 2
30 orifice 1
NGM5056UC BTU/hr kW
112 Front right 15,000 4.39
88 Front left 9,100 2.67
88 Rear left 9,100 2.67
65 Rear right 5,000 1.47
NGM8056UC, NGM8046UC BTU/hr kW
112 Center 15,000 4.39
65 Front Right 5,000 1.47
88 Front Left 9,100 2.67
65 Rear Left 5,000 1.47
88 Rear Right 9,100 2.67
NGMP056UC BTU/hr kW
106 Large Center
15,000* 4.39*
30 Small Center
65 Front Right 5,000 1.47
88 Front Left 9,100 2.67
65 Rear Left 5,000 1.47
88 Rear Right 9,100 2.67
*Combined rate of 106 and 30 orifices produce
15,000 BTU/ 4.39 kW.
NGMP656UC BTU/hr kW
106 Large Center
15,000* 4.39*
30 Small Center
88 Front Right 9,100 2.67
88 Front Left 9,100 2.67
88 Rear Left 9,100 2.67
65 Rear Right 5,000 1.47
*Combined rate of 106 and 30 orifices produce
15,000 BTU/ 4.39 kW.
NGM5656UC,
NGM8656UC, NGM8646UC
BTU/hr kW
112 Center 15,000 4.39
88 Front Right 9,100 2.67
88 Front Left 9,100 2.67
88 Rear Left 9,100 2.67
65 Rear Right 5,000 1.47
7 mm socket driver
(3 inch minimum exten-
sion)
Flat blade screwdriver,
small thin blade
Adjustable wrench
and/or
slip joint pliers
Scissors