Operation Manual

Table Of Contents
Setting up VCA
Several VCA configurations are available.
Off
Silent VCA
Profile #1
Profile #2
Scheduled
Event triggered
VCA - Silent VCA
In this configuration, metadata is created to facilitate searches
of recordings, however, no alarm is triggered.
4 In the VCA configuration drop-down list, select Silent VCA.
No parameters can be changed for this selection.
VCA - Profiles
Two profiles can be set up with different VCA configurations
1. In the VCA configuration drop-down list, select profile 1 or
2 and enter the required settings.
2. If necessary, click Default to return all settings to default
values.
To rename a profile:
1. To rename the file, click the icon to the right of the list field
and enter the new profile name in the field.
2. Click the icon again. The new profile name is saved.
The current alarm status is displayed for information purposes.
Aggregation time [s]
Set an aggregation time of between 0 and 20 seconds. The
aggregation time always starts when an alarm event occurs. It
extends the alarm event by the value set. This prevents alarm
10
10.1
10.2
10.2.1
76 en | Setting up VCA
Camera Browser
Interface
2016.09 | v1.632 | AM18-Q0718 Bosch Security Systems