Alarm output
Configure the switching behavior of the output.
Select different events that automatically activate an output. For
example, turn on a floodlight by triggering a motion alarm and
then turn the light off again when the alarm has stopped.
Idle state
Select Open for the output to operate as a normally open
contact, or select Closed if the output is to operate as a
normally closed contact.
Operating mode
Select the way the output works.
For example, if you want an activated alarm to stay on after the
alarm ends, select Bistable. If you wish an activated alarm to
stay on for ten seconds for example, select 10 s.
Output follows
Select the event that triggers the output.
Output name
The alarm output can be assigned a name here. This name
appears on the Live page.
Toggle output
Click the button to switch the alarm output manually (for
example, for testing purposes or to operate a door opener).