Design Guide

1–800–944–2904 | bosch-home.com/us
Refrigeration — Benchmark
®
Series Built-in Refrigeration
Planning Information | Benchmark
®
Series | Refrigeration | 195194 | Refrigeration | Benchmark
®
Series | Installation Options
The Bosch Built-in Refrigeration Collection offers a variety of installation possibilities*. In some instances, special accessories are required.
Recommended Installations Considerations
Stand-Alone
Any appliance can be installed as a stand-alone unit. Ensure a cutout
flush to the appliance at a depth of minimum 4" (102 mm), preferably
6" (152 mm) on the top and sides.
Side-By-Side When two appliances are installed side-by-side a sealing kit must be
used. For combinations that involve a freezer column, this kit is
provided. For all other (non-traditional) side-by-side combinations or
instances where any appliances are installed less than 6" (152 mm)
apart from one another but not connected side-by-side, purchase the
Heater Kit (HEATKITB80).
Split Columns
With Partition
When dimensioning the partition, note the thickness of the door
panel (including handles) as well as the swivel range to prevent
damage if the doors are opened at the same time. (See page 196 for
details on door swivel range dimensions)
Three appliances can be installed together only if a partition —
minimum
5
/
8
" (16 mm) — is placed between two of the appliances.
Ensure that door panel thickness (including handles) as well as the
swivel range are accounted for.
At The End of
a Cabinetry Run
All appliances must be completely enclosed on the top and sides.
If one side of the appliance is visible, a decorative side panel must be
used. The side panel must be connected firmly to the wall, the floor
and any overhead furniture / fixtures before the appliance is placed in
the cutout.
Not Recommended Concerns
It is absolutely essential to ensure that the appliance is installed in
such a way that the doors do not interfere with an adjacent wall or
other kitchen elements. (See page 196 for details on door swivel
range dimensions)
A partition — minimum
5
/
8
" (16 mm) — is required to ensure the doors
do not interfere with one another when opened. Use a partition to
separate appliances and observe the door swivel range. (See page
196 for details on door swivel range dimensions)
A French Door Bottom Freezer cannot be connected side-by-side
with any other appliance. Use a partition to separate appliances and
observe the door swivel range. (See page 196 for details on door
swivel range dimensions)
*The Bosch warranty shall apply only to recommended installations.
Installation Options
Benchmark
®
Series Built-in Refrigeration
Planning Information
Benchmark
®
Series Built-in Refrigeration
Electrical Specifications
The appliance comes with a 3-wire power supply cord.
UL listed in the USA.
The appliance requires a 3-wire receptacle that is fitted with
a 15 Amp fuse or higher. Refer to the following table for max
load details.
The receptacle must be installed by a licensed electrician only.
For the installation position of the receptacle refer to diagram
in “Electrical Location”.
Grounding Instruction
This appliance must be grounded. In the event of a malfunction
or breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for the electric current.
Additional Grounding Procedure
Some local regulations may require a separate ground. In such
cases, the required accessory ground wire, clamp and screw
must be purchased separately. Never ground the appliance to
plastic plumbing lines, gas lines or water pipes.
A 4-conductor cord shall be used when the appliance is
installed in an area where local codes do not permit grounding
through the neutral. Power supply cord must be replaced by a
licensed electrician only.
Warning
Improper connection of the equipment grounding conductor
may result in electric shock. Have the appliance checked by a
qualified electrician or service technician if you are in doubt as
to whether the appliance has been properly grounded.
Electrical Location
Side-by-Side Installation
Water Location
A cold water connection is required for appliances that feature
an ice maker or an ice and water dispenser.
The water pressure must be between 40 and 120 p.s.i.
(2.75‒8.25 bar). The installation must comply with local
plumbing regulations.
A separate shut-off valve must be installed for the appliance
water connection.
The shut-off valve for the water connection may not be behind
the appliance. It is recommended to place the shut-off valve
outside the cutout next to the appliance or in another easily
accessible location. When installing the water connection,
observe the permitted installation areas for the water supply
line. The supply line can be located to the right (a), to the left
(b), or underneath (c).
Appliance Max Load
120V AC, 60Hz
30-Inch Single Door Refrigerator 15 A
18-Inch Single Door Freezer* 15 A
30-Inch Bottom Freezer* 15 A
36-Inch French Door 15 A
*Including ice maker
Split Column Installation
18-Inch 30-Inch
X 18" (457 mm) 30" (762 mm)
Y 9" (229 mm) 15" (381 mm)