Operating/installations instructions

Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
1 Remove the trivets, burner caps and burner heads. 
2 Change the injectors using a 7-mm socket wrench 
and be sure to tighten them down properly so that 
3 Re-assemble the burner component parts in reverse 
order.
Natural Gas
Burner Injector
size
(mm)
Injector
size
(mm)(MJ)
Small
Medium
Large
0.90
1.18
0.50
0.67
0.85
0.97
To change injectors
All work involved in installation, setting and adaptation
to a different gas type must be carried out by authorised
personnel from our Service Centre and must comply
the local gas company.
Request change-over injectors from our customer service
deparment (refer injector chart below for sizes).
Coverting the cooktop
from Nat.Gas to
NOTE: it is not necessary to adjust the primary air control
on these burners.
6
7 mm
Hourly Gas
(MJ)
4,0
Refer Fig. .
7
they are fully airtight. Refer Fig. .
8
8
7
1.55
wok (Center or
Left)
Univcersal LPG
with current regulations and the conditions laid down by
Universal LPG
6,5
14,0
11.5
3,25
6,25
13,25
Hourly Gas
1.70
9.5
11
Consumption
Consumption