Spec Sheet

filters (recommended for recirculation extraction against an
internal wall or in an island bench).
-
- cleanAir odor filters: Lifetime of 360 hours of cooking (non-
regenerative).
-
- Low-noise filters with optimized psycho-acoustics.
-
- Large scale filter surface with high odor reduction
capabilities.
-
- Optimized odor reduction performance for cooking
applications with complex odor molecules (e.g. fish).
-
- Easy-to-access and easy-to-remove from above.
-
- Replenishment cleanAir filter set 17004806 (HEZ9VRCR0)
available via customer service.
-
- Convenient one-hand removal of unit via floating glass
ceramics handle.
-
Integrated, large-scale, high performance stainless-steel
grease filters with 12 filtration layers and one black top layer
for enhanced aesthetical integration.
-
All parts of the unit are easy-to-clean, fully dishwasher safe
and heat resistant.
-
(Upper) Liquid collector unit with 200ml of capacity for
standard accidental spillages or cooking condensate.
-
Powerful drainage system for spillages that exceed 200ml of
liquids.
-
Liquid safety collector with additional capacity of 700ml for
more severe accidental situations. Dishwasher safe. Easily
accessible and detachable from below.
-
Overall capturing capacity of 900ml (200ml + 700ml).
-
Watertight blower system.
-
- Noise level in ducted extraction (Sound power level
according to EN 60704-3): min. normal setting42 dB re 1 pW,
max. normal setting69 dB re 1 pW, max. Boost-/Intensive
setting74 dB re 1 pW.
-
- Noise level in recirculated extraction (Sound power level
according to EN 60704-3. ): min. normal setting41 dB re 1
pW, max. normal setting68 dB re 1 pW, max. Boost-/Intensive
setting72 dB re 1 pW.
-
- Grease filter efficiency (according to EN 61591)94 %.
Technical Information
-
Appliance measurements (H/W/D):223 mmx802 mmx522 mm
-
Installation dimensions: (H x W x D)223 mmx750 mmx490 mm
-
Installation into 60 cm floor cupboard possible
-
Min. worktop thickness:16 mm
-
Length wire connection:110 cm
-
7.4 KWtotal connected load
-
Cable included
Planning & installation notes
-
Suitable for ducted or recirculated extraction installations.
Respective mandatory installation acessories required:
-
- HEZ9VEDU0 for ducted extraction
-
- HEZ9VRPD0 for fully ducted and partly-ducted recirculation
with cleanAir odor filters. Recommended for extraction
against an external wall. Additional ducts are required.
Installation kit HEZ9VRUD0 for unducted recirculation with
cleanAir odor filters. Recommended for extraction inside the
kitchen such as an island bench setting or an internal wall.
-
Planning suggestions:
-
- Installation is possible in island as well as wall oriented
configurations.
-
- The max. immersion depth is 223mm below glass for
top mounted appliances and 227mm for flush installed
appliances.
-
- The minimum worktop thickness is 16mm for top mounted
and flush installed appliances with the standard installation
system. Installation in even thinner worktops is also possible
with the spare part: 626792.
-
- The overall appliance weight is 26kg - the bearing capacity
and stability, in the case of very thin worktops in particular,
must be supported using suitable substructures. The overall
appliance weight and the worktop manufacturer's structural
integrity specifications are to be taken into account.
-
- The appliance must be freely accessible from below (i.e. for
accessing the lower liquid safety collector).
-
- No false floor is necessary below the cooktop with
integrated downdraft ventilation system. The drawers and/or
shelves in the floor unit must be removable. The backpanel of
the floor unit can be kept - only a cut-out for the air outlet is
needed (position and size can be taken from the installation
instructions).
-
- Installation kit HEZ9VRUD0 for unducted recirculation
enables easy and quick installations and can be planned in all
worktop depths ≥60cm. For ducted installations - in ducted
extraction (HEZ9VEDU0) as well as fully or partly ducted
recirculation (HEZ9VRPD0) - a worktop depth of ≥70cm is
required.
-
- Installation kit HEZ9VRUD0 for unducted recirculation
requires a vertical aperture of min. 25mm behind the
backpanel of the furniture. Suggested for ideal performance
are 50mm.
-
- For partly ducted and unducted recirculation extraction
installations, a return-flow aperture of ≥400cm² is to be
respected in the plinth area. The aperture can be realized
via outlet grids, lamella grids or subtly shortened plinths
depending on the assortment of the kitchen furniture
manufacturer.
-
- The air outlet on the backside of the appliance can directly
be accessed with a male flat duct element (DN 150).
-
- The pressuredrop resistant blower allows longer and more
complex ductings up to 8m with three 90° bows while keeping
sufficient performance.
-
- In ducted extraction configuration a one-way flap (or
backflow trap) with a maximum opening pressure of 65Pa
should be installed.
-
For ducted extraction configuration: 2 x 2 Battery of directly
integrated, high-performance low-noise acoustic filters for
significantly lower noise and improved psycho-acoustics.
-
- The product complies with the Needle Flame Test (according
to IEC 60695-5-11), the V2 flammability class (according to
UL94) and the B1 building material class (DIN 4102-1). The
3/6