Specifications

Flash pattern Function
On Steady
Trouble state. Indicates a trouble condition
exists. Examine the other LEDs to determine
the trouble condition.
Off
LED trouble state. Indicates the module is
not powered up, or there is a failure in the
module. Check for proper installation.
Table 8.8: Heartbeat LED descriptions
Flash pattern Function
RX (Receive)
Flashing
Occurs every time a packet is received on-air.
TX (Transmit)
Flashing
Occurs every time a packet is transmitted on-
air.
Table 8.9: RX and TX LED descriptions
Refer to the module’s Installation and Operation Guide for more information on the LEDs and
troubleshooting.
Compatible receivers for IP communication
Sending Conettix IP Ethernet reports or Modem4 telephone reports requires a Bosch central
station receiver firmware update when existing equipment is in place. The following receivers
are compatible with
B5512/B4512/B3512 control panels when updated to the listed CPU
versions and managed with the listed software version:
Receiver CPU version D6200 version Formats
Conettix D6600 Communications Receiver/
Gateway (with D6641 line cards installed
only)
01.10.00 2.00 Contact ID
Modem4
Conettix D6100IPv6 Communications
Receiver/Gateway
61.10.00 2.00 Contact ID
Modem4
Conettix D6100i Communications
Receiver/Gateway
61.10.00 2.00 Contact ID
Modem4
8.5
Control Panel IP communications | en 53
Bosch Security Systems, Inc. Installation and System Reference Guide 2014.05 | 11 | F.01U.287.180