Installation and Operating Guide

Problem solving
Greentherm T9900 SE/i – 6 720 813 635 (2022/01)
72
F3 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If appliance’s configuration is required:
See section 6.6 to configure appliance (region,
power, type and gas type) and perform an automatic
combustion adjustment according to the
section 8.12.
1)
If the problem persists:
Replace electronic control unit.
1)
F7 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F8 Electronic control unit internal error. Reset error (touch and hold on/off button for 3
seconds).
If the problem persists:
Replace electronic control unit.
1)
F9 Gas valve driver internal fault. Check gas valve wire connections.
1)
If the problem persists:
Replace the wire connections and/or electronic
control unit.
1)
FA Gas leakage in the gas path (gas valve or gas
manifold shut-off valves).
Replace the gas valve and/or gas manifold.
1)
After gas valve and/or gas manifold replacement
perform gas and air tuning ( section 8.12).
1)
FC Touch screen key pressed for more than 20
seconds.
Release the touch screen key.
Clean the touch screen display.
Display reads
SOLAR but without
existence of solar
thermal system.
Display reads
SOLAR and water
temperature low.
Power demand lower than appliance minimum
output power.
Increase hot water flow.
increase setpoint temperature.
Display shows a red
X.
HMI (display) is not communicating with Electronic
Control Unit.
Reset the appliance by unplugging it for some
seconds (at least 10) and plug it back in.
Replace the HMI (display) and/or wire connections
and/or electronic control unit.
High pitch noise
(whistling)
Combustion flame with gas in excess or lack of air. Check if gas type is correct ( section 6.8).
1)
Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.12).
1)
Low pitch noise
with vibration
(rumbling)
Combustion flame with air in excess or lack of gas. Check if gas type is correct ( section 6.8).
1)
Check gas inlet pressure ( section 4.13).
1)
Perform gas and air tuning ( section 8.12).
1)
1) only to be carried out by qualified contractors.
2) see temperature resistance charts in fig. 68 and 69.
3) Error reset also possible by shutting-off water flow to the unit, and turning it back on.
Display Description Solution