en Important Safeguards 1. Read, Follow, and Retain Instructions - All safety and operating instructions should be read and followed before operating the unit. Retain instructions for future reference. 2. Heed Warnings - Adhere to all warnings on the unit and in the operating instructions. 3. Attachments - Attachments not recommended by the product manufacturer should not be used, as they may cause hazards. 4. Installation Cautions - Do not place this unit on an unstable stand, tripod, bracket, or mount.
iv en Safety Precautions Sécurité Attention : l'installation doit exclusivement être réalisée par du CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates the presence of uninsulated “dangerous voltage” within the product’s enclosure that can cause an electric shock.
UMM Series Public View Monitor Mounts | en v Preface This guide describes how to mount the UMS Series Public View Monitor using the UMM-LP10 Feed-through Pipe Mount or the UMM-LW10 Feed-through Wall Mount. Audience This guide is intended for qualified installation and service personnel who are familiar with the applicable national and local electrical codes. Document Conventions Convention Bold Bold Italic Underline Meaning Denotes a part, item, or assembly.
vi en | F01U029704 | 1.0 | 2006.07 UMM Series Public View Monitor Mounts Mounting Manual Bosch Security Systems, Inc.
UMM Series Public View Monitor Mounts Table of Contents | en vii Table of Contents 1 Unpacking 1 1.1 1.1 Parts List 1 2 Description 2 3 Installation 3 3.1 Wiring Requirements 3 3.2 Installing the Feed-through Pipe Mount (UMM-LP10B) 4 3.2.1 Mounting the UMS Public View Monitor to a freely rotating pipe mount: 5 3.2.2 Mounting the UMS Public View Monitor to a stationary pipe mount: 7 3.
viii en | Table of Contents F01U029704 | 1.0 | 2006.07 UMM Series Public View Monitor Mounts Mounting Manual Bosch Security Systems, Inc.
UMM Series Public View Monitor Mounts 1 Unpacking | en 1 Unpacking This equipment should be unpacked and handled with care. If an item appears to have been damaged in shipment, notify the shipper. Verify that all parts shown in the Parts List are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. The original packing carton is the safest container in which to transport the unit. Save it for possible future use. 1.1 1.
2 2 en | Description UMM Series Public View Monitor Mounts Description The UMM Series is a mounting solution designed to install an LCD monitor to a pipe or to a wall. The UMM-LP10B and UMM-LW10B mounts are capable of supporting a maximum load of 25 lbs (11.34 Kg). F01U029704 | 1.0 | 2006.07 Mounting Manual Bosch Security Systems, Inc.
UMM Series Public View Monitor Mounts 3 Installation | en 3 Installation This section provides detailed instructions on how to install the UMM-LP10B Feed-through Pipe Mount and the UMM-LW10B Feed-through Wall Mount. 3.1 Wiring Requirements Both UMS Public View Monitor models (UMS-20xxxA and UMS-20xxxC) feature various connectors used to transmit video, receive video and to deliver power to the unit.
4 en | Installation 3.2 UMM Series Public View Monitor Mounts Installing the Feed-through Pipe Mount (UMM-LP10B) This mount attaches to a 1.5-in. NPT pipe (not provided). Ensure that you have the contents of the UMM-LP10B Hardware Kit, the two (2) Wago® clamps (included with the UMS Public View Monitor packaging) and a 3/32-in. Allen Wrench (not included). The combined weight of the monitor and the mount is 16 lbs (7.26 Kg).
UMM Series Public View Monitor Mounts Installation | en 5 3.2.1 Mounting the UMS Public View Monitor to a freely rotating pipe mount: 1. Loosen the four (4) thumbnuts enough to allow the pipe extension to rotate. 2. Tilt the pipe extension end approximately 30° to 30° allow the cables to feed through easily. 3.
6 8. en | Installation UMM Series Public View Monitor Mounts Tighten the set screw to secure the mounting to recording device plate end. 9. Remove the tape from the cables. to power supply 10. Connect the external 24 VAC power leads from the power supply to the unused end of the Wago clamp, which is connected to power leads from the monitor. Connect the coax cables if necessary. 8 11. Screw the 1.5-in.
UMM Series Public View Monitor Mounts Installation | en 7 3.2.2 Mounting the UMS Public View Monitor to a stationary pipe mount: 1. Carefully remove the four (4) thumbnuts and washers from the back of the mounting plate. Then, separate the pipe extension end from the mounting plate. 1 2. Feed the 24 VAC power leads from the power supply and the coax cable (if present) into the end of the pipe and through the 2 pipe extension. 3.
8 4. en | Installation UMM Series Public View Monitor Mounts Ensure that the power leads from the monitor are staggered (or offset). 5. Feed the cables from the back of the UMS Public View Monitor through the hole in the middle of the mounting plate. 5 6. Attach the mounting plate end of the UMM-LP10B to the monitor using the four (4) screws and four (4) washers provided in the hardware kit. Tighten securely. 7. 6 Connect one (1) Wago clamp to the end of each power lead from the monitor. 8.
UMM Series Public View Monitor Mounts 3.3 Installation | en 9 Installing the Feed-through Wall Mount (UMM-LW10B) This mount attaches to a wall surface as described in the procedure below. The combined weight of the monitor and the mount is 17 lbs (7.71 Kg); it is recommended to use four (4) 3/8-in. bolts to attach the mount to the wall. Ensure that you have the contents of the UMMLW10B Hardware Kit, the two (2) Wago® clamps (included with the UMS Public View Monitor packaging) and a 3/32-in.
10 en | Installation UMM Series Public View Monitor Mounts Mounting the UMS Public View Monitor to the wall mount 1. Loosen the four (4) thumbnuts enough to allow the pipe extension to rotate. 2. 1 Feed the cables from the back of the UMS Public View Monitor into the middle of the mounting plate; then thread the cables up through the mount. Pull the wires through the top of the pipe 2 extension end. 3.
UMM Series Public View Monitor Mounts 4 Dimensional Outlines | en 11 Dimensional Outlines ø2.25 7.0 4.6 2.3 4.6 Fig. 4.1 UMM-LP10B 10-inch Pipe Mount–in inches ø 5.0 4.6 12.0 4.6 13.4 Fig. 4.2 UMM-LP10B 12-inch Wall Mount–in inches Bosch Security Systems, Inc. Mounting Manual F01U029704 | 1.0 | 2006.
12 en | Dimensional Outlines F01U029704 | 1.0 | 2006.07 UMM Series Public View Monitor Mounts Mounting Manual Bosch Security Systems, Inc.
Americas: Bosch Security Systems 130 Perinton Parkway Fairport, New York, 14450 USA Phone +1 800 289 0096 Fax +1 585 223 9180 www.boschsecurity.us © Bosch Security Systems, Inc. 2006 Europe, Middle East, Asia: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands Phone +31 (0) 40 27 83955 Fax +31 (0) 40 27 86668 www.boschsecurity.com Asia-Pacific: Bosch Security Systems Pte Ltd. 38C Jalan Pemimpin Singapore 577180 Phone +65 6319 3450 Fax +65 63139 3499 www.boschsecurity.