Technical data
DANGER
Death by electrocution possible due to live parts with more than 50V!
⇒ Open the machine sockets of the motor only when the system has been de-
energized!
1. Open the main switch
2. Ensure that the main switch cannot be accidentally switched on again
3. Loosen the screws of the power plug cover and remove the cover.
4. Assemble the sealing air connection.
When positioning the cover, ensure that the cable wires and
seals are not damaged.
Screw the power plug cover with the sealing air connection onto the motor.
Torque of the screws = 1.3 Nm.
5. Connect the quick-acting pneumatic coupling of the accessory set to the
regulated compressed air source.
The sealing air unit is now ready for operation.
Project Planning Manual | Rexroth IndraDyn S Electric Drives
and Controls
| Bosch Rexroth AG 139/194
Accessories and Options