Technical data

Ordering type Power wire cross-
section
Terminal area, outer cable diameter [mm]
RLS1101/C02 1,0 / 1,5 11,0 – 14,0
Fig.8-10: Order designation for RLS1101 plug
8.3 Power Connector Size 1.5
8.3.1 RLS1200 Flange Socket
In motors of frame size MSK070, MSK071, the power is supplied by using a
flange socket RLS1200.
Fig.8-11: Flange Socket RLS1200
Protection class Number of pins Temperature range Contact type
IP66 / IP67 plug-
ged
3 + PE + 5 -40 °C to +125 °C Pin
Fig.8-12: Mechanical data
Rated voltage Continuous rated
current
Degree of pollution Overvoltage catego-
ry
630 V / 125 V
max. 57.0 A depend-
ing from the wire
cross-section
3
III (according to DIN
VDE 0110)
Fig.8-13: Electrical data
Order designation for plugs
Graphical representation
Mechanical data
Electrical data
144/194 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDyn S | Project Planning Manual
Connection Techniques