Technical data

Rated voltage Continuous rated
current
Degree of pollution Overvoltage catego-
ry
630 V / 125 V
max. 57.0 A depend-
ing from the wire
cross-section
3
III (according to DIN
VDE 0110)
Fig.8-17: Electrical data
U1 Power
V1 Power
W1 Power
PE Grounding
5 Temperature sensor KTY84 (T1 TM+)
6 Temperature sensor KTY84 (T2 TM-)
7 Holding brake (Br+ / +24V)
Option
8 Holding brake (Br- / 0V)
9 Brake / temp. shield
Fig.8-18: RLS1201 – contact assignment for MSK motors
Ordering type Power wire cross-section Terminal area, outer cable di-
ameter [mm]
RLS1201/C02 1,5 9,0 – 12,7
RLS1201/C04 2,5 / 4,0 13,0 – 17,3
RLS1201/C06 6,0 17,5 – 21,5
RLS1201/C10 10,0 21,5 – 26,0
Fig.8-19: Order designation for RLS1201 plug
Electrical data
Contact assignment
Order designation for plugs
146/194 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDyn S | Project Planning Manual
Connection Techniques