Technical data
Environmental factor Unit Class 2K3
Low air temperature °C - 25
High air temperature °C + 70
Max. rel. air humidity % 95
Max. absolute air humidity g/m³ 60
Shock stress see fig. 9-6 "Permitted shock load for MSK motors" on
page 158
Fig.10-5: Conditions for transport
The following conditions must be maintained during transport:
● Use suitable means for transport and heed the weight of the components.
You can find indications of weight on the data sheets or on the type plate
of the motor.
● Provide shock absorbability if strong vibrations may occur during trans-
port.
● Transport the motors only in the horizontal position.
10.5 Storage of the Equipment
Requirements for storage according to DIN EN 60271-3-1.
Environmental factor Unit Class 1K3
Low air temperature °C - 5
High air temperature °C + 45
Low rel. air humidity % 5
High rel. air humidity % 95
Low absolute air humidity g/m³ 1
High absolute air humidity g/m³ 29
Shock stress see fig. 9-6 "Permitted shock load for MSK motors" on
page 158
Fig.10-6: Conditions for storage
CAUTION
Damage and invalidation of the warranty due to incorrect storage!
⇒ Store the motors horizontally in a dry, vibration-free, dust-free and corrosion-
protected location.
178/194 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDyn S | Project Planning Manual
Handling, Transport and Storage