Technical data

Environmental factor Unit Class 2K3
Low air temperature °C - 25
High air temperature °C + 70
Max. rel. air humidity % 95
Max. absolute air humidity g/m³ 60
Shock stress see fig. 9-6 "Permitted shock load for MSK motors" on
page 158
Fig.10-5: Conditions for transport
The following conditions must be maintained during transport:
Use suitable means for transport and heed the weight of the components.
You can find indications of weight on the data sheets or on the type plate
of the motor.
Provide shock absorbability if strong vibrations may occur during trans-
port.
Transport the motors only in the horizontal position.
10.5 Storage of the Equipment
Requirements for storage according to DIN EN 60271-3-1.
Environmental factor Unit Class 1K3
Low air temperature °C - 5
High air temperature °C + 45
Low rel. air humidity % 5
High rel. air humidity % 95
Low absolute air humidity g/m³ 1
High absolute air humidity g/m³ 29
Shock stress see fig. 9-6 "Permitted shock load for MSK motors" on
page 158
Fig.10-6: Conditions for storage
CAUTION
Damage and invalidation of the warranty due to incorrect storage!
Store the motors horizontally in a dry, vibration-free, dust-free and corrosion-
protected location.
178/194 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDyn S | Project Planning Manual
Handling, Transport and Storage