Technical data
12 Commissioning, Operation and Maintenance
12.1 Commissioning
CAUTION
Material damage due to errors in the controls of motors and moving
elements! Unclear operating states and product data!
● Do not carry out commissioning if connections, operating states or product
data are unclear or faulty!
● Do not carry out commissioning if the safety and monitoring equipment of
the system is damaged or not in operation.
● Damaged products may not be operated!
● Contact Rexroth for missing information or support during commissioning!
The following notes on commissioning refer to IndraDyn S motors as part of a
drive system with drive and control devices.
Preparation
1. Keep the documentation of all applied products ready.
2. Check the products for damage.
3. Check all mechanical and electrical connections.
4. Activate the safety and monitoring equipment of the system.
5. Make sure that the optional holding brake is ready for operation. chapter
12.4.5 "Holding Brakes " on page 185
Execution
When all prerequisites have been fulfilled, proceed as follows:
1. Activate the optional motor cooling fan unit or liquid cooling.
2. Carry out the commission of the drive-system according to the instructions
of the respective documentation. You can find the respective information
in the functional description of the drive-devices.
Commissioning of drive controllers and the control unit may require
additional steps. The inspection of the functioning and performance of the
systems is not part of the commissioning of the motor; instead, it is carried
out within the framework of the commissioning of the machine as a whole.
Observe the information and regulations of the machine manufacturer.
12.2 Operation
Keep the described ambient conditions during operation.
12.3 Deactivation
In the case of malfunctions or maintenance, or to deactivate the motors, pro-
ceed as follows:
1. Observe the instructions of the machine documentation.
2. Use the machine-side control commands to bring the drive to a controlled
standstill.
3. Switch off the power and control voltage of the drive controller.
4. Only at motors with blowers: Switch off the motor protection switch for the
motor blower.
Project Planning Manual | Rexroth IndraDyn S Electric Drives
and Controls
| Bosch Rexroth AG 183/194
Commissioning, Operation and Maintenance