Adjustment procedure DC-iris Lens:
1. Unlock the focus locking screw.
2. SET BACK FOCUS NOW is highlighted in the menu.
3. Turn the focus adjustment as required.
4. Lock the focus locking screw.
5. Exit the menu selection.
Defaults submenu
Camera control communication
This camera is equipped with a coaxial communications transceiver. In
combination with VP-CFGSFT, the camera can be adjusted from the head-
end side of the coaxial cable. All menus can be accessed remotely giving
full control of the camera. With this communication it is also possible to
disable the local keys on the camera. To avoid loss of communication on
an installed camera, the Communication ON/OFF selection is not
available while using remote control. This function can only be accessed
with the camera buttons.
Function Selection Description
SET
FOCUS
NOW
Forces the lens to fully open the iris. Adjust the lens
focus now.
COMM ON, OFF Bilinx communication ON/OFF
HEATER AUTO, OFF Select AUTO to enable the thermostatically
controlled heater function
DEFAULTS Select submenu Return all settings for all modes to factory defaults
EXIT Exit the menu
Function Selection Description
ALL
DEFAULTS
Select to restore the factory defaults. A confirmation
screen appears. Allow 5 seconds for the camera to
optimize the picture after a mode reset.