Datasheet

Switching and Control | Switching and Control Systems | 453
Table is based on a nominal 24 VAC source with a 10%
drop in voltage due to cable loss.
Technical Specifications
Electrical
Model No. Rated
Voltage
1
Voltage
Range
Pan/Tilt, Aux
1
,
& Aux Supply
LTC 8561/60
2
120 VAC,
50/60 Hz
100 to 130 120 VAC,
50/60 Hz
LTC 8566/60
3,5
120 VAC,
50/60 Hz
100 to 130 24 VAC,
50/60 Hz
LTC 8566/50
4,5
230 VAC,
50/60 Hz
198 to 264 24 VAC,
50/60 Hz
LTC 8561/50
2
230 VAC,
50/60 Hz
198 to 264 230 VAC,
50/60 Hz
LTC 8564/20
2
24 VAC,
50/60 Hz
20 to 28 24 VAC,
50/60 Hz
1. Power (all models): 15
W at rated voltage (not including pan/tilt).
2. Fuse protected at 2.0
A.
3. Fuse protected at 1.0
A.
4. Fuse protected at 0.4
A.
5. For the LTC
8566/60 and LTC
8566/50, the maximum total current output, including
Pan/Tilt output, Auxiliary 1 output, and Auxiliary Supply output, is 2.0
A.
Pan/Tilt Output 4 function pan/tilt solid state drive with zero
crossing turn-on; 1.0 A drive capability
Lens Output
For Zoom, Focus, and
Motorized Iris
6 VDC or 12 VDC, 100 mA maximum
Variable Speed 6 VDC
Setting
4 VDC to 8 VDC
Variable Speed 12 VDC
Setting
8 VDC to 16 VDC
Auto-pan Auxiliary Out-
put
1
Solid state drive with zero crossing turn-on;
1.0 A drive capability
Auxiliary Output 2, 3,
and 4
Relay contact rating 250 VAC, 5.0 A resistive,
0.25 hp
Pre-positions 99, with 4 functions each for use with 355° pan/
tilt drivers or 82 with 5 functions each for use
with continuous pan/tilt drivers. Pan/tilt posi-
tions sensed at 10-bit accuracy. Note that the
maximum number of pre-positions available in
the system is dependent on the type of control
system employed. Refer to the applicable con-
troller specification for exact pre-position capa-
bilities.
Mechanical
Size
(H x W x D)
295 x 241 x 165 mm (11.6 x 9.5 x 6.5 in.)
Weight 6.8 kg (15 lb)
Environmental
Temperature
Operating
–40°C to 60°C (–40°F to 140°F)
Storage
–40°C to 70°C (–40°F to 158°F)
Humidity 0% to 95% relative, non-condensing
Vibration 3 g swept sine wave, 15 Hz to 2000 Hz
Shock 50 g, 11 ms, 1/2 sine
Enclosure Protection NEMA-4X, IP66, Enclosure Type RJ 1008 HPL
Ordering Information
LTC 8561/50 Single-channel On-site
Receiver/Driver
230 VAC pan/tilt voltage, 230 VAC power
supply, with auxiliary, 50°Hz
LTC 8561/50
LTC 8561/60 Single-channel On-site
Receiver/Driver
120 VAC, 50/60 Hz, 100 to 130 V; Pan/Tilt,
Aux 1, and Aux Supply: 120 VAC, 50/60 Hz
LTC 8561/60
LTC 8564/20 Single-channel On-site
Receiver/Driver
24 VAC, 50/60 Hz, 20 to 28 V; Pan/Tilt, Aux
1, and Aux Supply: 24 VAC, 50/60 Hz
LTC 8564/20
LTC 8566/50 Single-channel On-site
Receiver/Driver
230 VAC, 50/60 Hz, 198 to 264 V; Pan/Tilt,
Aux 1, and Aux Supply: 24 VAC, 50/60 Hz
LTC 8566/50
LTC 8566/60 Single-channel On-site
Receiver/Driver
120 VAC, 50/60 Hz, 100 to 130 V; Pan/Tilt,
Aux 1, and Aux Supply: 24 VAC, 50/60 Hz
LTC 8566/60
www.boschsecurity.com Bosch Security Systems B.V.
8