Datasheet

464 | Switching and Control | Switching and Control Systems
Typical “Others” to Biphase Configuration
# Description
1 “Others”Controller
2 “Others” Code Distribution Unit
3 Power Supply
4 “Others” Code
5 LTC 8782 Translator
6 Biphase Control Code
7 Bosch Dome and P/T/Z Cameras
8 “Others” Dome Camera
9 Allegiant Receiver/Driver
Parts Included
Qty. Components
1 Code Translator Unit
1 Power Supply
LTC 8782/60 Series: TC120PS
LTC 8782/50 Series: TC220PS
1 Plastic Bezel
1 Rack-mount Hardware Kit
1 Instructions for Use
Technical Specifications
Electrical
Input Voltage (Adapter Included)
LTC 8782/60 Series 120 VAC
LTC 8782/50 Series 230 VAC
Voltage Range
LTC 8782/60 Series 100132 VAC
LTC 8782/50 Series 198264 VAC
Translator Model Number Voltage Range @ Specified Cur-
rent
LTC 8782/x0-01 918 VAC/VDC @ 300 ma
LTC 8782/x0-03
LTC 8782/x0-04
LTC 8782/x0-05
LTC 8782/x0-10
LTC 8782/x0-11
LTC 8782/x0-12
LTC 8782/x0-13
LTC 8782/x0-14
LTC 8782/x0-02 1218 VAC/VDC @ 150 ma
LTC 8782/x0-21
LTC 8782/x0-22
LTC 8782/x0-24
LTC 8782/x0-25
LTC 8782/x0-30
LTC 8782/x0-31
LTC 8782/x0-32
Environmental
Temperature
Operating 4°C to 50°C (39°F to 122°F)
Storage 40°C to 70°C
(40°F to 158°F)
Humidity < 90% non-condensing
Mechanical
Finish Black
Dimensions
(H x W x D)
4.1 x 14.0 x 14.0 cm
(1.6 x 5.5 x 5.5 in.)
Weight 0.7 kg (1.5 lb)
Rack-mount Kit (included) For EIA 48 cm (19 in.) rack. One (1)
unit high rack kit will hold up to three
(3) units across.
Dimensions
(H x W)
4.5 x 48.3 cm
(1.8 x 19.0 in.)
Connectors Screw terminals
Ordering Information
LTC 8782/50‑01 Code Translator
Biphase to Vicon RS-422 translator, to
RCL translator 230 VAC, 50/60 Hz
LTC 8782/50-01
LTC 8782/50‑02 Code Translator
Biphase to American Dynamics Manchester
translator, 230 VAC, 50/60 Hz
LTC 8782/50-02
LTC 8782/50‑03 Code Translator
Biphase to Sensormatic RS-422 translator,
230 VAC, 50/60 Hz
LTC 8782/50-03
LTC 8782/50-04 Code Translator
Biphase to Kalatel RS-422 translator,
230 VAC, 50/60 Hz
LTC 8782/50-04
Bosch Security Systems B.V. www.boschsecurity.com
8