Datasheet

504 | Switching and Control | Digital Motion Detectors
VMD
Type Digital image analysis; multi-level changes
in illumination, texture and motion; primari-
ly outdoor applications (indoor use accept-
able)
Results Display Superimposed in video-out signal, yellow
outline = initial position;
red outline = present position;
green = trajectory (B/W-lines if B/W signal
at video-in)
Alarm Image Storage
Alarm Images Five (5) pre-alarm images, one (1) alarm
image, ten (10) post-alarm images
VMD Results Superimposed outlines, fade out after five
(5) seconds
Access Via rotary switch on front panel or remote
controlled (toggle) between live image and
image storage; forward and backward step-
ping
Operation Modes
1 Reset of Alarms Automatic
Normal Operation Live image on video-out
Object Detection Superimposed outlines in live image on vid-
eo-out (last alarm sequence in storage)
2 Reset of Alarms Manual
Normal Operation Live image on video-out
Object Detection Superimposed outlines in live image on vid-
eo-out (first, not reset alarm sequence in
storage)
3 Reset of Alarms Manual
Normal Operation Live image on video-out
Object Detection Automatic switchover to the alarm image
storage / first alarm image with superim-
posed outlines on video-out (first, not reset
alarm sequence in storage)
Security
Passcode Five (5) digits
Video Signal Signal loss, bad signal-to-noise ratio, cam-
era
Supervision Blinded, insufficient scene illumination
Mounting Possibilities
Desktop (stand alone or as stack), wall or ceiling mounted (use VMD-WM),
48‑cm (19‑in.) rack mounted (use VMD-RA90 or VMD-RA00)
Mechanical
Dimensions
(H x W x D)
110 x 48 x 207 mm (4.3 x 1.88 x 8.1 in.)
Weight 0.5 kg (1.1 lb) (without mouse and power
supply unit)
Environmental
Operating Temperature 0°C to 45°C (32°F to 113°F)
Operation Humidity 8% to 80% (relative, non-condensing)
Ordering Information
VMD01‑M50 Digital Motion Detector
single-channel, stand alone, indoor and out-
door, 50 Hz, 5 VDC, 6 W
VMD01-M50
Accessories
VMD‑PS90 Power Supply
for VMD01-Mx0, required if using as a single
stand alone unit,
100–240 VAC/5 VDC, max. 2.4 A, cord
2.0 m, 4 x 0.6 with RJ-11 plug (+5 V to
1.2 V; GND to 4.6), 4 different adapters in-
cluded for UK, US, Europe and AUS, approxi-
mately 85 x 50 x 32 mm
(3.28 x 1.93 x 1.24 in.) (depth without con-
tacts)
VMD-PS90
VMD‑SM Serial Mouse
required for set-up for VMD01-Mx0
Note: This product has not been listed by UL.
VMD-SM
VMD‑RA90 Rack Mount
48-cm (19-in.), with power supply for up to
eight VMD01-Mx0, 3VU, depth: 378 mm
(14.88 in.), including eight bracket sets for
VMD01 mounting, power supply: primary
110–230 VAC, Euro and US power cord
1.5 m (4.92 ft), secondary 8x5 VDC, 8 x 2 A
(including cable set)
Note: This product has not been listed by UL
and is currently not for sale in the United
States and Canada.
VMD-RA90
VMD‑RA00 Rack Mount
48-cm (19-in.), without power supply, 3 VU,
depth: 378 mm (14.88 in.), including eight
bracket sets for VMD01 mounting
VMD-RA00
VMD‑RADC Front Panel Covers
dummy cover for VMD‑RA00 and VMD‑RA90,
set of 4
VMD-RADC
VMD‑WM Wall Mount Bracket
for one (1) VMD01‑Mx0, 165 x 205 x 10 mm
(6.6 x 8.05 x 0.39 in.), 0.4 kg (0.99 lb)
VMD-WM
Bosch Security Systems B.V. www.boschsecurity.com
8