Specifications

Bosch
24-6 Camera Handler Release Notes
resolution value on Stream 2.
Due to the NVR web client known issue, when setting the resolution for the second H264
stream, set it on the advance edit page. This is due to the fact it is a copy setting of H264 stream
1 on camera list page with editing status, and real available resolution may not be included in the
copy of the resolution list.
Due to camera known issue, for Dinion HD 1080P D/N IVA camera, set resolution 4CIF
(704x480) on H264 Stream 1 and 768x432 on H264 Stream 2, then the user only can get an
actual resolution 704x432 for H264 Stream 1. And set resolution 768x432 on H264 Stream 1
and 4CIF (704x480) on H264 Stream 2, user can only get actual resolution of 704x432 for H264
Stream 1.
Green line at top of victor Unified Client live stream on Bosch AutoDome Jr 800HD. This is a
camera issue, we can find a green line on top of player when play H264 stream from Bosch
AutoDome Jr 800 HD by VLC directly.
Special Points
Bosch camera has 8 profile configurations on the web page, and each profile may configure a
set of codec parameters. Handler specifies H264 Stream 1 on camera to profile Configure 1 and
H264 Stream 2 on camera to profile Configure 2 and the MJPEG stream on camera to profile
Configure 3, so when the NVR sets stream codec parameters, the parameter is written in the
special profile configured.
Changes to codec parameters should only be made on the NVR web GUI and not the camera
web page as they may not be implemented.
The ranges of Brightness and Contrast are 0-255 in Bosch cameras. The Handler converts this
value to 0-100 using the following formulae:
Camera to NVR: Camera(brightness/contrast)*100/255
NVR to camera: NVR(brightness/contrast)*255/100
When adding the camera to the NVR, the GOP structure must be set to "IP" in profile configure
of the camera web page, so the FPS value is usable.
The default GOP is 15, when the stream restarts, the default value will be set. If the user would
like to set the GOP value only after the stream on the NVR restarts.
When enabling audio stream on NVR for all Bosch cameras, ensure audio is enabled on camera
web GUI.