Specifications
Appendix Bosch Security Systems | 2006-03 | V2.0
EN | 116 Installation and Operating Manual | VIP X1600
No connection estab-
lished, no image
transmission.
The module's configuration. Check all configuration parame-
ters.
Faulty installation. Check all cables, plugs, contacts
and connections.
Wrong IP address. Check the IP addresses (terminal
program).
Faulty data transmission
within the LAN.
Check the data transmission with
ping.
The maximum number of
connections has been
reached.
Wait until there is a free connection
and then call the sender again.
No audio transmis-
sion to remote sta-
tion.
Hardware fault. Check that all connected audio
units are operating correctly.
Faulty cable connections. Check all cables, plugs, contacts
and connections.
Incorrect configuration. Check the configuration of the
audio settings (gain and activa-
tion).
The module does not
report an alarm.
Alarm source is not selected. Select possible alarm sources on
the Alarm sources configuration
page.
No alarm response speci-
fied.
Specify the desired alarm response
on the Alarm connections config-
uration page, change the
IP address if necessary.
Control of cameras
or other units is not
possible.
The cable connection
between the serial interface
and the connected unit is not
correct.
Check all cable connections and
ensure all plugs are properly fitted.
The interface parameters do
not match those of the other
unit connected.
Make sure that the settings of all
units involved are compatible.
The module is not
operational after a
firmware upload.
Power failure during pro-
gramming by firmware file.
Have the module checked by Cus-
tomer Service and replace if neces-
sary.
Incorrect firmware file. Enter IP address of the module fol-
lowed by /main.htm in your Web
browser and repeat the upload.
Malfunction Possible causes Solution