Alarm inputs
Each VIP X1600 module contains four alarm inputs for triggering external alarm
devices, for example door contacts or sensors. When configured appropriately,
an alarm device can for example trigger the unit to automatically establish a con-
nection with a remote station. A zero potential make contact or switch can be
used as the actuator.
Note
If possible, use a bounce-free contact system as the actuator.
Connection is via the terminal connector. See page 118 for the pin assignment.
Relay outputs
Each VIP X1600 module contains four relay outputs for switching external
devices, for example lights or alarm sirens. You can operate these relay outputs
manually while there is an active connection to the device. The output can also
be configured to automatically activate sirens or other alarm units in response to
an alarm signal.
Caution
A maximum load of 30 V and 2 A may be applied to the relay contacts.
Connection is via the terminal connector. See page 118 for the pin assignment.
Audio connections
The audio versions of the VIP X1600 modules contain two line inputs for a total
of four mono inputs, which are automatically assigned to the four camera inputs.
The audio signals are transmitted at the same time as the video signals.
The stereo jack plugs must be connected as follows:
Contact Audio In 1/2 Audio In 3/4
Tip Line In 1 Line In 3
Middle ring Line In 2 Line In 4
Lower ring Ground Ground