Operation Guide
Table Of Contents
- VideoJet X40
- Table of Contents
- 1 Preface
- 2 Safety Information
- 3 Product Description
- 4 Installation
- 5 Configuration Using a Web Browser
- 5.1 Connecting
- 5.2 Configuration Menu
- 5.3 Basic Mode: Unit Access
- 5.4 Basic Mode: Date/Time
- 5.5 Basic Mode: Network
- 5.6 Basic Mode: Encoder Profile
- 5.7 Basic Mode: Audio
- 5.8 Basic Mode: Recording
- 5.9 Basic Mode: System Overview
- 5.10 Advanced Mode: Identification
- 5.11 Advanced Mode: Password
- 5.12 Advanced Mode: Date/Time
- 5.13 Advanced Mode: Display Stamping
- 5.14 Advanced Mode: Appearance
- 5.15 Advanced Mode: LIVEPAGE Functions
- 5.16 Advanced Mode: Logging
- 5.17 Advanced Mode: Video Input
- 5.18 Advanced Mode: Picture Settings
- 5.19 Advanced Mode: Encoder Profile
- 5.20 Advanced Mode: Audio
- 5.21 Advanced Mode: Storage Management
- 5.22 Advanced Mode: Remote Video Device
- 5.23 Advanced Mode: Recording Profiles
- 5.24 Advanced Mode: Retention Time
- 5.25 Advanced Mode: Recording Scheduler
- 5.26 Advanced Mode: Recording Status
- 5.27 Advanced Mode: Alarm Connections
- 5.28 Advanced Mode: VCA
- 5.29 Advanced Mode: VCA Profiles
- 5.30 Advanced Mode: VCA Scheduled
- 5.31 Advanced Mode: VCA Event Triggered
- 5.32 Advanced Mode: Audio Alarm
- 5.33 Advanced Mode: Alarm E-Mail
- 5.34 Advanced Mode: Alarm Task Editor
- 5.35 Advanced Mode: Alarm Inputs
- 5.36 Advanced Mode: Relay
- 5.37 Advanced Mode: COM1
- 5.38 Advanced Mode: Network
- 5.39 Advanced Mode: Advanced
- 5.40 Advanced Mode: Multicasting
- 5.41 Advanced Mode: JPEG Posting
- 5.42 Advanced Mode: Encryption
- 5.43 Advanced Mode: Maintenance
- 5.44 Advanced Mode: Licenses
- 5.45 Advanced Mode: System Overview
- 5.46 Function Test
- 6 Operation
- 7 Maintenance and Upgrades
- 8 Appendix
- 9 Specifications
- 10 Glossary
- 11 Index
VideoJet X40 Installation | en 19
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
4 Installation
4.1 Preparations
The VideoJet X40 features industrial standard equipment and is therefore suitable for both
stationary installation and mobile installation in vehicles.
Please ensure the following installation conditions:
– Do not install the unit close to heaters or other heat sources. Avoid locations exposed to
direct sunlight.
– Allow sufficient space for running cables.
– Ensure that the unit has adequate ventilation.
– When making connections, use only the cables supplied or use appropriate cables
immune to electromagnetic interference.
– Position and run all cables so that they are protected from damage, and provide
adequate cable strain relief where needed.
– Avoid impacts, blows and severe vibrations that exceed the specification limits (see
Section 9 Specifications, page 119), as these can irreparably damage the unit.
4.2 Mounting
The VideoJet X40 can be permanently mounted to walls, below ceilings or other load-bearing
locations using the four drillings in the unit's base.
!
CAUTION!
The unit is intended for use indoors or in housings.
Select a suitable location for installation that guarantees to meet the environmental
conditions. The ambient temperature must be between –30 and +60 °C (–22 and +140 °F).
The relative humidity must not exceed 95%.
The VideoJet X40 generates heat during operation, so you should ensure that there is
adequate ventilation and enough clearance between the unit and heat-sensitive objects or
equipment.
!
CAUTION!
The front panel of the VideoJet X40 (video inputs) must not be pointing upwards, as internal
heat dissipation is not guaranteed in this position. All other installation positions are
permitted.
Make sure that the mounting location (for example wall or ceiling) can reliably hold the unit.
The load bearing capacity must be adequate for four times the weight of the unit.
For mounting on metal, use screws with the following minimum specification:
M4 × 8, 8.8, DIN ISO 4017.
For mounting on concrete, use screws with the following minimum specification:
M4 × 40 mm (1.57 in) and 6 mm (0.23 in) plastic dowels, for example fischer S4, type 50106.