Operation Guide
Table Of Contents
- VideoJet X40
- Table of Contents
- 1 Preface
- 2 Safety Information
- 3 Product Description
- 4 Installation
- 5 Configuration Using a Web Browser
- 5.1 Connecting
- 5.2 Configuration Menu
- 5.3 Basic Mode: Unit Access
- 5.4 Basic Mode: Date/Time
- 5.5 Basic Mode: Network
- 5.6 Basic Mode: Encoder Profile
- 5.7 Basic Mode: Audio
- 5.8 Basic Mode: Recording
- 5.9 Basic Mode: System Overview
- 5.10 Advanced Mode: Identification
- 5.11 Advanced Mode: Password
- 5.12 Advanced Mode: Date/Time
- 5.13 Advanced Mode: Display Stamping
- 5.14 Advanced Mode: Appearance
- 5.15 Advanced Mode: LIVEPAGE Functions
- 5.16 Advanced Mode: Logging
- 5.17 Advanced Mode: Video Input
- 5.18 Advanced Mode: Picture Settings
- 5.19 Advanced Mode: Encoder Profile
- 5.20 Advanced Mode: Audio
- 5.21 Advanced Mode: Storage Management
- 5.22 Advanced Mode: Remote Video Device
- 5.23 Advanced Mode: Recording Profiles
- 5.24 Advanced Mode: Retention Time
- 5.25 Advanced Mode: Recording Scheduler
- 5.26 Advanced Mode: Recording Status
- 5.27 Advanced Mode: Alarm Connections
- 5.28 Advanced Mode: VCA
- 5.29 Advanced Mode: VCA Profiles
- 5.30 Advanced Mode: VCA Scheduled
- 5.31 Advanced Mode: VCA Event Triggered
- 5.32 Advanced Mode: Audio Alarm
- 5.33 Advanced Mode: Alarm E-Mail
- 5.34 Advanced Mode: Alarm Task Editor
- 5.35 Advanced Mode: Alarm Inputs
- 5.36 Advanced Mode: Relay
- 5.37 Advanced Mode: COM1
- 5.38 Advanced Mode: Network
- 5.39 Advanced Mode: Advanced
- 5.40 Advanced Mode: Multicasting
- 5.41 Advanced Mode: JPEG Posting
- 5.42 Advanced Mode: Encryption
- 5.43 Advanced Mode: Maintenance
- 5.44 Advanced Mode: Licenses
- 5.45 Advanced Mode: System Overview
- 5.46 Function Test
- 6 Operation
- 7 Maintenance and Upgrades
- 8 Appendix
- 9 Specifications
- 10 Glossary
- 11 Index
VideoJet X40 Configuration Using a Web Browser | en 85
Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06
5.40 Advanced Mode: Multicasting
In addition to a 1:1 connection between an encoder and a single receiver (unicast), the
VideoJet X40 can enable multiple receivers to receive the video signal from an encoder
simultaneously. The device either duplicates the data stream itself and then distributes it to
multiple receivers (Multi-unicast) or it sends a single data stream to the network, where the
data stream is simultaneously distributed to multiple receivers in a defined group (Multicast).
For each encoder (video input) you can enter a dedicated multicast address and port for each
stream. You can switch between the streams by clicking the appropriate tabs.
A special IP address (class D address) must be configured for multicast operation in a
multicast-enabled network.
The network must support group IP addresses and the Internet Group Management Protocol
(IGMP V2). The address range is from 225.0.0.0 to 239.255.255.255.
The multicast address can be the same for multiple streams. However, it will be necessary to
use a different port in each case so that multiple data streams are not sent simultaneously
using the same port and multicast address.
Enable
To enable simultaneous data reception on several receivers you need to activate the multicast
function. To do this, check the box. You can then enter the multicast address.
i
NOTICE!
Multicast operation requires a multicast-enabled network that uses the UDP and the Internet
Group Management IGMP protocols. Other group management protocols are not supported.
The TCP protocol does not support multicast connections.
i
NOTICE!
You must set the parameters for each encoder (video input) and for each stream individually.