Operation Guide
Table Of Contents
- VideoJet X40
- Table of Contents
- 1 Preface
- 2 Safety Information
- 3 Product Description
- 4 Installation
- 5 Configuration Using a Web Browser
- 5.1 Connecting
- 5.2 Configuration Menu
- 5.3 Basic Mode: Unit Access
- 5.4 Basic Mode: Date/Time
- 5.5 Basic Mode: Network
- 5.6 Basic Mode: Encoder Profile
- 5.7 Basic Mode: Audio
- 5.8 Basic Mode: Recording
- 5.9 Basic Mode: System Overview
- 5.10 Advanced Mode: Identification
- 5.11 Advanced Mode: Password
- 5.12 Advanced Mode: Date/Time
- 5.13 Advanced Mode: Display Stamping
- 5.14 Advanced Mode: Appearance
- 5.15 Advanced Mode: LIVEPAGE Functions
- 5.16 Advanced Mode: Logging
- 5.17 Advanced Mode: Video Input
- 5.18 Advanced Mode: Picture Settings
- 5.19 Advanced Mode: Encoder Profile
- 5.20 Advanced Mode: Audio
- 5.21 Advanced Mode: Storage Management
- 5.22 Advanced Mode: Remote Video Device
- 5.23 Advanced Mode: Recording Profiles
- 5.24 Advanced Mode: Retention Time
- 5.25 Advanced Mode: Recording Scheduler
- 5.26 Advanced Mode: Recording Status
- 5.27 Advanced Mode: Alarm Connections
- 5.28 Advanced Mode: VCA
- 5.29 Advanced Mode: VCA Profiles
- 5.30 Advanced Mode: VCA Scheduled
- 5.31 Advanced Mode: VCA Event Triggered
- 5.32 Advanced Mode: Audio Alarm
- 5.33 Advanced Mode: Alarm E-Mail
- 5.34 Advanced Mode: Alarm Task Editor
- 5.35 Advanced Mode: Alarm Inputs
- 5.36 Advanced Mode: Relay
- 5.37 Advanced Mode: COM1
- 5.38 Advanced Mode: Network
- 5.39 Advanced Mode: Advanced
- 5.40 Advanced Mode: Multicasting
- 5.41 Advanced Mode: JPEG Posting
- 5.42 Advanced Mode: Encryption
- 5.43 Advanced Mode: Maintenance
- 5.44 Advanced Mode: Licenses
- 5.45 Advanced Mode: System Overview
- 5.46 Function Test
- 6 Operation
- 7 Maintenance and Upgrades
- 8 Appendix
- 9 Specifications
- 10 Glossary
- 11 Index
88 en | Configuration Using a Web Browser VideoJet X40
DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems
5.43 Advanced Mode: Maintenance
Firmware
The VideoJet X40 is designed in such a way that its functions and parameters can be updated
with firmware. To do this, transfer the current firmware package to the unit via the selected
network. It will then be automatically installed there.
In this way, a VideoJet X40 can be serviced and updated remotely without a technician having
to change the installation on site.
You obtain the current firmware from your customer service or from the download area at
www.boschsecurity.com.
1. First store the firmware file on your hard drive.
2. Enter the full path of the firmware file in the field or click Browse to locate and select the
file.
3. Next, click Upload to begin transferring the file to the unit. The progress bar allows you
to monitor the transfer.
The new firmware is unpacked and the Flash EPROM is reprogrammed. The time remaining is
shown by the message going to reset Reconnecting in ... seconds. The unit reboots
automatically once the upload has successfully completed.
If the Connect LED lights up red, the upload has failed and must be repeated. To perform the
upload you must now switch to a special page:
1. In the address bar of your browser, enter /main.htm after the IP address of the
VideoJet X40 (for example 192.168.0.10/main.htm).
2. Repeat the upload.
!
CAUTION!
Before launching the firmware upload make sure that you have selected the correct upload
file. Uploading the wrong files can result in the unit no longer being addressable, in which
case you must replace the unit.
You should never interrupt the installation of firmware. An interruption can lead to the flash-
EPROM being incorrectly programmed. This in turn can result in the unit no longer being
addressable, in which case it will have to be replaced. Even changing to another page or
closing the browser window leads to an interruption.